  • Mobile Cylinder Div.Dump Product & Quick Reference GuideCatalog HY18-0032/US

  • 2 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Copyright 2009, Parker Hannifi n Corporation, All Rights Reserved

    FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

    This document and other information from Parker-Hannifi n Corporation, its subsidiaries and au-thorized distributors provide product or system options for further investigation by users having technical expertise.

    The user, through its own analysis and testing, is solely responsible for making the fi nal selec-tion of the system and components and assuring that all performance, endurance, mainte-nance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.

    To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifi cations provided by the user, the user is responsible for determining that such data and specifi cations are suitable and suffi cient for all applications and reasonably foreseeable uses of the components or systems.

    WARNING - USER RESPONSIBILITY

    The items described in this document are hereby offered for sale by Parker Hannifi n Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the "Offer of Sale".

    Offer of Sale

  • 3 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Table of Contents

    General Information ..................................................................................................................4

    Features and Benefi ts ...............................................................................................................5

    Hydraulic Cylinder Model Number Coding .............................................................................7

    Mounting Options and Code Chart ..........................................................................................8

    Hydraulic Cylinder Load & Displacements .............................................................................9

    Closed Length Calculations for Single-Acting Single & Multiple Stage Cylinders ...........10

    Safety Precautions for Single-Acting Telescopic Cylinders ................................................12

    Genuine Replacement Service Repair Kits ...........................................................................14

    Hydraulic Cylinder Required Service Tools ..........................................................................15

    Normal Maintenance Items .....................................................................................................16

    Hydraulic Oil Recommendations ...........................................................................................17

    Standard Test Procedure for Hydraulic Cylinders ................................................................18

    Storage and Installation ..........................................................................................................19

    Front Mount Dump Body Stroke & Lifting Calculations .....................................................20

    Commodities & Materials Approximate Weights ..................................................................21

    Dump Hoist Type Identifi cation Chart ....................................................................................22

    Dump Trailer Type Identifi cation Chart ..................................................................................23

    Single-Acting Telescopic Cylinders With CC, DB, and DC MountsDesign .........................24

    Single-Acting Telescopic Cylinders With MB and MC MountsDesign ................................30

    Quick Reference Guide ...........................................................................................................31

    Safety Guidelines for Mobile Cylinder Division Products ...................................................52

    Offer of Sale .............................................................................................................................53

  • 4 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    General Information

    Cylinders were among the fi rst hydraulic products of Commercial Hydraulics beginning in 1928. In 2000 Commercial Intertech Corp. merged with the Parker Hannifi n Corp. Today, the Parker Mo-bile Cylinder Division is recognized as one of the largest independent manufacturers of hydraulic cylinders for mobile equipment and a leading supplier to refuse, mining, truck, material handling and positioning markets. Parkers Mobile Cylinder Division products include double- and single-acting telescopic cylinders, rod cylinders and smart cylinders with internal electronic controls.

    Additionally, the company enjoys a reputation for quality custom built cylinders that demonstrate engineering know how and adept manufacturing. Cylinders represent a signifi cant portion of the companys Hydraulic Systems sales - their contribution has resulted in signifi cant capital expen-ditures geared to establish Parkers Mobile Cylinder Division as the worlds leading manufacturer of hydraulic cylinders.

    About our Quick Reference and Application Guide . . .

    Its our goal to provide our customers with the highest quality cylinders. If the need arises for a cylinder not listed in this guide, please furnish us the following information and well do our best to provide a new or replacement.

    * OEM identifi cation number * Retract or closed length * Single- or double-acting type * Stroke length * Outside diameter of the largest * Extend or open length moving stage or rod and bore diameters * Pineye sizes * Number of moving stages * Plunger mount type * Application * Base mount type Please refer to the cylinder specifi cation data forms for more information.

    Parkers Mobile Cylinder Division has complete manufacturing facilities to fi ll all your cylinder needs from 1 piece to 1000 pieces. If youre looking for a prototype, a special cylinder, or a production run, Parkers Mobile Cylinder Division is the place to call.

    Parker Hannifi n Corp. Phone: 800-848-5575Mobile Cylinder Div. Fax: 800-694-3392P.O. Box 239 E-mail: [email protected], OH 44501-0239 www.parker.com

    DISCLAIMERCROSSOVER AND APPLICATION DATA IS FOR REFERENCE ONLY.

    NO OTHER CONDITIONS ARE EXPRESSED OR IMPLIED. The information in this publication has been independently obtained from a wide variety of sources. However, the publisher disclaims any warranty expressed or implied or any liability or responsibility for the accuracy or correctness of any calculation or information which is critical, it should be independently verifi ed.

  • 5 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    * Longer sleeve overlap for improved stability and higher column loading.

    * Nylon tipped set screws that conform to the shape of the packing nut threads. It is nearly impossible for the packing nut to back off accidentally.

    * Snap-on, glass-fi lled bearings that absorb contaminants without damaging cylinder walls.

    * Threaded steel stop rings for easier servicing and more reliable stopping action.

    * External packing nuts give added support to the tube exterior while making service procedures easier.

    * Wave springs and chevron packing for self-compensating seals.

    * Polyurethane rod wipers that resist higher temperatures without extrusion.

    * Positive manual air bleeder prevents cavitation and mushy cylinder action, NOW BLEEDRELESS.

    * Cast steel mountings offer dependable strength. Pin-eye and rod-end are welded into a single unit.

    OUR DESIGN ADVANTAGES INCLUDE:

    Features and Benefi ts

  • 6 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    CustomerUnmet Need:Bleeding cylinders is a tough dirty job for the dump truck and trailer industry. No one really wants to bleed the cylinder because it is a dirty, dangerous, and environmentally hazardous job as the mechanic must climb in and out of the dump bed to adjust the bleeder screw. Failure to bleed the cylinder will result in early cylinder failure in addition to cylindermis-staging, and excessive costly hydraulic repairs.

    Solution:Parker has developed a special bleed system that is incorporated into the cylinder that allows air to bleed every time the dump bed goes up and down. This keeps the cylinder free of air and as a result the bleeding of oil and air is eliminated.

    Value Added:r 'MFFUTVTJOH1BSLFSTIJHIRVBMJUZDZMJOEFSTXJMMCFOFUCZTBWJOHUIFMBCPSDIBSHFTGSPNCMFFEJOHDZMJOEFSTUISPVHIPVUUIFMJGFUJNFPGUIF%VNQ#FE

    r0&.TTBWFBNJOJNVNPGHBMMPOPGIZESBVMJDPJMUP

    HBMMPOTPGPJMPOuBOEuDZMJOEFST'PSBUSBJMFSNBOVGBDUVSFrTFMMJOHBZFBSUIJTXPVMETBWFBZFBS

    Bleederless Telescopic CylindersInnovative Mobile Solutions From Mobile Cylinder Division

    Contact Information:1BSLFS)BOOJO$PSQPSBUJPOMobile Cylinder Division-PHBO"WFOVF:PVOHTUPXO0IJP

    phone 800 848 5575fax 800 694 [email protected]

    XXXQBSLFSDPN HY18-0027/US

    Product Features:r /PBJSUPCMFFEr /PTQFFEZESZUPTXFFQr /P&1"UPEFBMXJUIr /PNPSFDMJNCJOHJOUPEJSUZCFETr 'FXFSIZESBVMJDSFQBJSTr $PNQMFUFMZJOUFSDIBOHFBCMFXJUIBMMNBOVGBDUVSFrTDZMJOEFST

    r 4J[F3BOHFGSPNuUPUIFMBSHFTUuDZMJOEFST

    r 3FEVDFEXFJHIUPWFSTUBOEBSEDZMJOEFSTXJUICMFFEFSTDSFXT

    Bleederless Telescopic

  • 7 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Hydraulic Cylinder Model Number Coding

    The code and model numbers of a Parker Mobile (Commercial) Cylinder are references to its size and type. Using these numbers when ordering or inquiring greatly facilitates accurate understanding.

    The following are examples of Parker Mobile Cylinder code and model numbers.

    1. S = Single-acting Telescopic or Displacement Cylinder (Parker has also used SA, SF, and H as a prefi x) SD = Double-acting Telescopic Cylinder D = Double-acting Piston Rod Cylinder

    2. = Nominal O.D. of the largest moving stage on Single-acting and Double-acting Telescopic cylinders

    or the Nominal Bore of Double-acting Piston Rod Cylinders

    3. = Number of moving stages or sleeves in a Telescopic Cylinder

    4. = Mounting option on the body or base end of cylinder (See mounting Option and Code Chart for mount descriptions)

    5. = Mounting option on the rod or plunger end of cylinder (See mounting Option and Code Chart for mount descriptions)

    6. = Modifi cation or design variation of the cylinder

    7. = Length of cylinder stroke in inches

    * Longer sleeve overlap for improved stability and higher column loading.* Nylon tipped set screws that conform to the shape of the packing nut threads. It is nearly impossible for the packing nut to back off accidentally.* Snap-on, glass-filled bearings that absorb contaminants without damaging cylinder walls.* Threaded steel stop rings for easier servicing and more reliable stopping action.* External packing nuts give added support to the tube exterior

    while making service procedures easier.* Wave springs and chevron packing for self-compensating seals.* Polyurethane rod wipers that resist higher temperatures without extrusion.* Positive manual air bleeder prevents cavitation and mushy cylinder action, NOW BLEEDERLESS.* Cast steel mountings offer dependable strength. Pin-eye and rod-end are welded into a single unit.

    OUR DESIGN ADVANTAGES INCLUDE:

  • 8 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Mounting Options and Code Chart

    ABCDEFGHJKLMNOP

    Pin-Eye DrilledThru Rod

    Pin-Eye DrilledThru Lug

    PlainNo Mount

    Cross Tube

    Threaded

    Drilledand Tapped

    Flange Mountat Base

    Flange MountMid-Body

    Foot / Pad Mount

    CenterlineMount

    Double LugClevis Mount

    TrunnionMount

    Rod End Drilledand Tapped

    Ball Mount

    Socket Mount

    Body or Rod

    Rod

    Body or Rod

    Body or Rod

    Body or Rod

    Body or Rod

    Body

    Body

    Body

    Body

    Body or Rod

    Body

    Rod

    Body or Rod

    Body or Rod

    CodeLetter

    MountDescription

    MountSketch

    MountLocation

  • 9 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Hydraulic Cylinder Load & Displacements

    S SERIES SINGLE-ACTING, SINGLE & MULTIPLE STAGE CYLINDERS

    SD SERIES DOUBLE-ACTING, MULTIPLE STAGE CYLINDER

    Note: The Effective area to RETRACT a Standard SD series double acting multiple stage cylinder is the effective area of the PLUNGER (plunger bore area minus the plunger O.D. area).Example: Retract force for a SD94CC-8-190 (which has 5.75 O.D. plunger and fi ts in 6.25 bore) would be 9,426 lbs @ 2,000 psi, based on a 4.71 sq. in. effective area.

    To calculate effective area in square inches: Multiply diameter times diameter times .78Example: 5 dia. x 5 dia. = 25 x .78 = 19.63 Square inches of area

    To calculate load capacity / cylinder force: Multiply effective area times operating pressure (psi)Example: 19.63 Square inches x 1750 P.S.I = 34,361 lbs of force

    To calculate the required gallons of fl uid to extend a cylinder:Add each Displacement per inch of stroke (from chart) for the required sleeve sizes.Divide this total by the number of moving sleeves, then multiply that total by the desired cylinder stroke.Note: The Gallons required to extend does not include the necessary fl uid to fi ll an empty cylinder.

    Example: Required fl uid to extend a S83DC-40-134 single-acting telescopic cylinder with following stage sizes: 5.75" O.D.= .112 6.75" O.D.= .155 7.90" O.D.= .210 .477

    .447 3 = .159 gallons per inch of stroke.159 gallons per inch x 134" of stroke = 21.31 gallons to extend cylinder

    Sleeve or Plunger O.D.(in inches)

    Effective Areain square inches

    Load Capactitylbs @ 2000 p.s.i.

    Displacement per inchof stroke in gallons *

    1.75" 2.41" 4,811 0.0102.75" 5.94" 11,880 0.0263.75" 11.04" 22,089 0.0484.75" 17.72" 35,441 0.0775.75" 25.97" 51,935 0.1126.75" 35.78" 71,570 0.1557.90" 49.02" 98,034 0.2129.38" 69.03" 138,059 0.29910.75" 90.76" 181,526 0.39312.50" 122.72" 245,438 0.53114.00" 153.94" 307,877 0.666

    Sleeve orPlunger O.D.(in inches)

    Bore of Mainor Sleeve(in inches)

    Effective area(sq. inches)to extend

    Effective area(sq. inches)to retract

    Load capacitylbs @ 2000

    p.s.i. extending

    Load capacitylbs @ 2000

    p.s.i. retracting

    Displacementper inch of stroke

    (in gallons)*to extend

    Displacementper inch of stroke

    (in gallons)*to retract

    1.75" 2.25" 3.98" 1.57" 7,952 3,142 0.017 0.0072.75" 3.25" 8.29" 2.35" 16,592 4,712 0.036 0.0103.75" 4.25" 14.18" 3.14" 28,372 6,283 0.061 0.0144.75" 5.25" 21.64" 3.92" 43,296 7,854 0.094 0.0175.75" 6.25" 30.68" 4.71" 61,360 9,426 0.133 0.0206.75" 7.25" 41.28" 5.49" 82,564 10,994 0.179 0.0247.90" 8.44" 55.68" 6.97" 111,360 13,946 0.242 0.0309.38" 9.88" 76.59" 7.56" 153,180 15,120 0.332 0.03310.75" 11.50" 103.87" 13.11" 207,738 26,213 0.450 0.05712.50" 13.00" 132.73" 10.01" 265,465 20,028 0.575 0.04314.00" 14.50" 165.13" 11.19" 330,261 22,384 0.715 0.048

  • 10 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    * Closed length (Lc) for S Models is computed by one of the three equations below. Model number and stroke re-quired determines which equation to use. Example: To fi nd Lc for S41 cylinder with 68 stroke. Under S41 column, use equation III, because the stroke is over 50. (68 - 50)Lc = Stroke + X1 + X2 = 68 + 7.50 + 10 = 68 + 7.50 + (1.8)Use next largest whole number. = 68 + 7.50 + 2 = 77.50.

    The closed length (Lc) is 77.50. Add Lc 77.50 to the stroke 68 for extended length of 145.50

    AI

    B

    Lc

    C1 8/

    Lc

    D

    A

    C

    I

    B

    1 8/

    SINGLE STAGE 2 STAGE

    S31 S41 S51 S61 S71 S81 S91 S42 S52 S62 S72 S82 S92

    A 33/4 43/4 53/4 63/4 8 91/8 1013/16 A 43/4 53/4 63/4 8 91/8 1013/16

    B 43/8 53/8 63/8 73/8 85/8 97/8 113/4 B 53/8 63/8 73/8 85/8 97/8 113/4

    C 23/4 33/4 43/4 53/4 63/4 77/8 93/8 C 33/4 43/4 53/4 63/4 77/8 93/8

    D D 23/4 33/4 43/4 53/4 63/4 77/8

    E E

    F F

    Cylinder Dimensions (inches)Main Cylinder O.D.

    Largest Packing Nut O.D.

    1st Sleeve O.D.

    2nd Sleeve O.D.

    3rd Sleeve O.D.

    4th Sleeve O.D.

    H

    G

    H

    G

    I 3/4 3/4 3/4 1 1 11/4 11/4 I 3/4 3/4 1 1 11/4 11/4

    71 84 88 95 118 128 190 126 137 138 164 186 265

    X 5.75 5.75 5.75 6.00 6.00 6.50 6.62 X 6.69 6.69 6.94 6.94 7.44 7.56

    LCStroke + X

    up to 35" stroke LCStroke

    + X2up to 35" stroke

    X1 7.50 7.50 7.50 7.75 7.75 8.25 8.38 X1 8.44 8.44 8.69 8.69 9.19 9.31

    O.L. = 3 + X2O.L. = 3 + X2

    O.L. = 3O.L. = 3

    O.L. = 1 / 1 4O.L. = 1 / 1

    4

    LCStroke + X1

    36" to 50" stroke LCStroke

    + X 1236" to 50" stroke

    X2Stroke - 50

    10(To next largest whole number)

    X2Stroke - 50

    20(To next largest whole number)

    LCStroke + X1 + X2over 50" stroke LC

    Stroke+ X 1 + X 22

    over 50" stroke

    6th Sleeve O.D.

    5th Sleeve O.D.

    NPT Port

    Max. Stroke at 2000 PSI

    Equation I

    *To Find Closed Length - Lc

    Equation II

    Equation III

    Closed Length Calculations for Single-Acting Single & Multiple Stage Cylinders

  • 11 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Lc

    E

    C

    D

    AI

    B

    1 8/

    Lc

    F

    C

    D

    E

    AI

    B

    1 8/

    3 STAGE 4 STAGE

    S53 S63 S73 S83 S93 S64 S74 S84 S94

    A 53/4 63/4 8 91/8 1013/16 A 63/4 8 91/8 1013/16

    B 63/8 73/8 85/8 97/8 113/4 B 73/8 85/8 97/8 113/4

    C 43/4 53/4 63/4 77/8 93/8 C 53/4 63/4 77/8 93/8

    D 33/4 43/4 53/4 63/4 77/8 D 43/4 53/4 63/4 77/8

    E 23/4 33/4 43/4 53/4 63/4 E 33/4 43/4 53/4 63/4

    F F 23/4 33/4 43/4 53/4

    H

    G

    H

    G

    I 3/4 1 1 11/4 11/4 I 1 1 11/4 11/4

    181 186 204 224 312 238 262 265 352

    X 7.62 7.88 7.88 8.38 8.50 X 8.81 8.81 9.31 9.44

    LCStroke

    + X3up to 50" stroke

    LCStroke

    + X4up to 70" stroke

    X1 9.38

    O.L. = 3 + X2O.L. = 3 + X2

    O.L. = 3O.L. = 3

    O.L. = 1 / 1 4O.L. = 1 / 1

    4

    9.62 9.62 10.12 10.25 X1 10.56 10.56 11.06 11.19

    LCStroke

    + X 1351" to 75" stroke

    LCStroke

    + X 1471" to 100"

    X2Stroke - 75

    30(To next largest whole number)

    X2Stroke - 100

    40(To next largest whole number)

    LCStroke

    + X1 + X23over 75" stroke

    LCStroke

    + X1 + X24over 100" stroke

    Lc

    G

    C

    D

    E

    F

    AI

    B

    1 8/

    5 STAGE

    S75 S85 S95

    A 8 91/8 1013/16

    B 85/8 97/8 113/4

    C 63/4 77/8 93/8

    D 53/4 63/4 77/8

    E 43/4 53/4 63/4

    F 33/4 43/4 53/4

    H

    G 23/4 33/4 43/4

    I 1 11/4 11/4

    335 336 410

    X 9.75 10.25 10.38

    LCStroke

    + X5up to 85" stroke

    O.L. = 1 / 1 4

    O.L. = 3 + X2

    O.L. = 3

    X1 11.50 12.00 12.12

    LCStroke

    + X 1586" to 125" stroke

    X2Stroke - 125

    50(To next largest whole number)

    LCStroke

    + X1 + X25over 125" stroke

    Lc

    H

    G

    C

    D

    E

    F

    AI

    B

    1 8/

    6 STAGE

    A

    B

    C

    D

    E

    F

    H

    G

    I

    X

    LCStroke

    + X6up to 100 stroke

    O.L. = 1 / 1 4

    O.L. = 3 + X2

    O.L. = 3

    X1

    LCStroke

    + X 16101" to 150 stroke

    X2Stroke - 150

    60(To next largest whole number)

    LCStroke

    + X1 + X26over 150 stroke

    S86 S96

    91/8 1013/16

    97/8 113/4

    77/8 93/8

    63/4 77/8

    53/4 63/4

    43/4 53/4

    2

    33

    3

    /

    /

    4

    4

    3

    4

    3

    3

    /

    /

    4

    4

    11/4 11/4

    T.B.A. T.B.A.

    11.19 11.31

    12.94 13.06

    Closed Length Calculations for Single-Acting Single & Multiple Stage Cylinders

  • 12 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    WARNING!Telescopic cylinders commonly installed on dumping vehicles are devices intended to provide only a lifting force. The cylinder is not a structural member, and is not designed for, nor intended to provide stability to the dumping vehicle. Rollover or lateral tilt can cause the cylinder to bend, buldge or separate causing the dump body to drop suddenly, resulting in severe injury or death and/or damage to the unit and cylinder, if the following warnings are not observed.

    Hydraulic cylinders are not to be used as a stabilizer on a dump body or dump trailer. The hydraulic cylinder will not prevent the dump body or trailer from rollover or lateral tilt. The cylinder is strictly a lifting device and is not a structural member of the unit. Cylinders are not to be used as a means of stabilizing the unit.

    The hydraulic cylinder mounted in the unit should be free to fi nd its own trajectory line of extension, free of any lateral loading of the plungers. Misalignment of the top or bottom mountings, or mounting pins too tight, may cause scoring of the plungers, leaking, or improper sequencing which could cause the unit to upset.

    The hydraulic cylinder will not withstand lateral or side pressure when the unit is leaning. Only activate the cylinder when the tractor and trailer are in a straight line (not jack-knifed). A jackknife position of the tractor with the trailer is not recommended when dumping. In a jackknifed position, the upper coupler pivots on bearings, contributing nothing to dump stability. When the tractor and trailer are straight, the coupler bearings are normally 34 inches apart, assisting in stabilizing the dump.

    Do not activate the cylinder while on unlevel or soft ground, or during heavy crosswinds. Doing so may cause the unit to upset. Uneven terrain, causing the trailer wheels to be 3 1/2 inches to 4 inches higher than the other side, puts the top of the body 12 inches to 14 inches off center when the cylinder is fully extended. On fresh fi ll, loaded trailer wheels may sink on one side, again setting up potential tip over. On road construction, the crown is also critical on spread application, as in dumping on a slope. A 4 inch plus, height differential of wheels on an axle 8 feet wide, is another rollover potential. Do not attempt dumping operations in high gusty wind conditions. If possible, raise the dump body directly into the wind.

    A blown tire or a severely under infl ated tire can cause dump instability, when dumping. Always check tires visually for cuts or punctures by nails and metal. Make sure all tires are infl ated properly. Proper tire infl ation also improves wear and fuel economy.

    Do not activate the cylinder while personnel or equipment are alongside or behind the dump body or trailer.

    A hung load is commodity that does not discharge when a dump body is raised to an elevated position. This condition exists due to surface adhesion between the commodity and the interior of the dump body. To avoid a tip over due to a hung load, the driver should be warned by an observer or be aware of the materials moisture content, if this condition exists, immediately lower the dump body.

    The operator should stay at the controls during the entire dumping operation. An operator who fails to stay at the controls will never control the body when it starts to lean over for a tip over. If a problem exists, and the body starts to lean, the operator should immediately lower the dump body or trailer and check and remedy any potential problems, then resume dumping the load. It is important to slowly position the cylinder control valve into the hold position to avoid subjecting the cylinder to a high pressure.

    Do not overload the unit. The load must be distributed evenly during loading or unloading to avoid rollover and lateral tilt. Loads stuck while the cylinder is partially or completely extended increases the hazard of rollover and lateral tilt. Lower the dump body or trailer entirely with the cylinder control valve partially open (avoid lowering the dump body or trailer with the cylinder control valve completely open). Then unload the dump body or trailer manually or with an alternative mechanical aid.

    Overloading is a very common occurrence that aggravates all the above conditions that cause a tip over.

    Safety Precautions for Single-Acting Telescopic Cylinders

  • 13 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Safety Precautions for Single-Acting Telescopic Cylinders

    WARNING!Shock pressure can cause severe injury or death and/or damage to the unit and cylinder.Do not use the cylinder to loosen loads stuck in the dump body or trailer. Lower the dump body or trailer entirely with the cylinder control valve partially open (avoid lowering the dump body or trailer with the cylinder control valve completely open). Then unload the dump body or trailer manually or with an alternative mechanical aid.

    Humping is a rapid acceleration / deceleration method used to loosen a hung load from a trailer. If the load is off center and the trailer is moved, a tip over may occur. Also, serious damage to the hoist may occur if an extreme humping motion is used to get a sticky load out of the body.

    Do not move the truck and jam the brakes while the cylinder is partially or fully extended to loosen loads stuck in the dump body or trailer. Pulling forward (or backing up) and hitting the brakes, or lowering the body part way and then quickly engaging the valve in the HOLD or RAISE position will cause a tremendous pressure spike. This pressure spike may bulge or split one of the larger stages of the cylinder. Lower the dump body or trailer entirely with the cylinder control valve partially open (avoid lowering the dump body or trailer with the cylinder control valve completely open). Then unload the dump body or trailer manually or with an alternative mechanical aid.

    Do not move the truck until the dump body or trailer is lowered completely.

    WARNING!Over pressurizing the cylinder can cause severe injury or death and/or damage to the unit and cylinder.

    Do not operate a cylinder at pressures above factory recommended operating pressures (Normally 2,000 P.S.I. unless otherwise approved).

    WARNING!Worn or damaged hydraulic hoses can cause severe injury or death and/or damage to the unit and cylinder.

    Hydraulic hoses should be checked regularly and replaced if worn out or damaged.

    NOTICE!

    Do not drive the unit while the P.T.O. or hydraulic pump is engaged.

    The hydraulic oil should be checked and changed regularly to avoid contamination leading to internal cylinder damage.

    A damp to light fi lm of oil on each plunger indicates a good cylinder operation. A small accumulation of oil may be noticed on the plunger at the head nuts after many cycles. This should not be mistaken for packing leakage.

    Cylinder should be free of entrapped air. It is advisable to bleed air from the cylinder weekly to free entrapped air. This will result in a smoother operation.

    The cylinder should fl oat in the pin mountings. The cylinder should be installed with 1/8" to 3/16" of clearance between the pin and the pin hole if the mounting eye is wider than 5", or with 1/16" to 1/8" clearance if the mounting eye is less than 5" wide. There should be a clearance of 1/8" to 1/4" per side on eyes less than 5" wide and 1/4" to 1/2" clearance per side on eyes in excess of 5" wide. This is to allow the body to sway slightly while dumping, without putting a side load on the cylinder. The cylinder plunger or one of the sleeves should be extended a minimum of 1/4" when the dump body is in the down position.

    The cylinder end mounts should be lubricated regularly.

  • 14 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Repair KitsFor Standard Parker Single-acting, Dump Body Cylinders.

    Parker's genuine replacement parts are available in kits to rebuild or repack our dump body cylinders. These parts are the same as originally installed. As with all hydraulic repairs, be sure your shop is properly equipped and that the work area is clean. Rebuilding kits consist of: 1. Wiper Rings 5. Piston Bearings 2. Packing Assemblies 6. Set Screws 3. Gland Bearing Rings 7. Nylon Balls 4. Wave Springs Repacking kits consist of: 1. Wiper Rings 2. Packing Assemblies Ordering Information Please order by part number

    Cylinder Packing InstallationRemove shims from packing set and measure packing height under fi nger pressure. Add one shim for each 1/32 that the packing measures under 1-1/8. Mea-sure depth to top of stop ring from top of tube. This dimension should be 2-1/4, however, it may vary slightly due to seating of the stop ring. Add one shim to the packing set for every 1/32 that this dimension measures over 2-1/4 or remove one shim from the packing set for every 1/32 that this dimension measures under 2-1/4. Install wave spring with gap edge against top of the cylinder stop ring. Soak packing in hydraulic oil for a few minutes. (Check bottom adapter. Only hard type can be used with the wave spring). Install packing, one ring at a time, in the proper sequence as shown in the sketch. Note: The soft, low pressure ring must be in the second position from the pressure side. Installed packing height need not be checked because wave spring will vary this

    Stop Ring

    Wave Spring

    Packing Nut

    Set Screw(remove before backing

    off packing nut)

    Wiper

    Vee-PackingAssembly

    Vee-PackingShims

    Bearing Ring

    Low Pressure RingHard Bottom Adaptor

    Nylon Ball

    2 1/4"1 1/8"WorkingHeight 1/8" 1"

    Cylinder Model Rebuild Kit Number Repack Kit NumberS53 Series A300-253 375-1804-017 A300-11 391-1804-020S62 Series A300-256 375-1804-020 A300-262 375-1804-026S63 Series A300-254 375-1804-018 A300-104 391-1804-109S64 Series A300-257 375-1804-021 A300-230 391-1804-237S73 Series A300-255 375-1804-019 A300-238 375-1804-002S74 Series A300-258 375-1804-022 A300-239 375-1804-003S84 Series A300-259 375-1804-023 A300-49 391-1804-054S85 Series A300-260 375-1804-024 A300-22 391-1804-060S95 Series A300-261 375-1804-025 A300-240 375-1804-004

    dimension. Installation of bearing and packing nut will compress wave spring for proper packing pre-load. Pull down tight against tube.

    Genuine Replacement Service Repair Kits

    The recommended store for a cylinder seal kit is to keep at room temperature and store in a sealed plastic bag protected from light. Shelf life will vary by composite and storage conditions. Properly stored seal kits can have a shelf life from 3 - 7 years.

  • 15 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    ToolsRequiredProper tools make the job of servicing cylinders easier and faster and reduce the possibility of damaging the finely machined surfaces. We recommend that you have the tools shown on this page prior to attempting service on Commercial telescopic cylinders. Tools with an * are required for all cylinders regardless of size. Lifting rings and stop ring wrenches must be ordered to fi t the specifi c sleeve in the cylinder.

    ADJUSTABLESPANNER WRENCH

    G3067-84K-4376-3067-006

    CHEVRONASSEMBLY TOOL

    M3067-2376-9067-001

    CYLINDERPACKING PULLER

    V3067-1376-9067-003

    CYLINDERBEARING PULLER

    M3067-4376-3067-001

    STRAP WRENCHP3067

    376-9067-002

    PISTON RING PLIERM3067-3K

    376-3067-015

    Sleeve orMain O.D.

    3 3/4"4 3/4"5 3/4"6 3/4"7 7/8"9 3/8"

    11 1/8"

    Sleeve orPlunger O.D.

    2 3/4"3 3/4"4 3/4"5 3/4"6 3/4"7 7/8"9 3/8"

    Eng # , Part NumberBC3067-1, 376-3067-008BC3067-2, 376-3067-009BC3067-3, 376-3067-010BC3067-4, 376-3067-011BC3067-5, 376-3067-012BC3067-6, 376-3067-013BC3067-7, 376-3067-014

    Eng # , Part NumberBA3067-1, 376-6067-047BA3067-2, 376-6067-048BA3067-3, 376-6067-049BA3067-4, 376-6067-050BA3067-5, 376-6067-051BA3067-6, 376-6067-052BA3067-7, 376-6067-053

    Lifting RingBC3067 Series

    Stop Ring WrenchBA3067 Series

    Sleeve orMain I.D.

    3 1/4"4 1/4"5 1/4"6 1/4"7 1/4"

    8 7/16"9 7/8"

    STO

    PR

    ING

    WR

    ENCH

    SLEE

    VEO

    RM

    AIN

    BAR

    REL

    O.D.I.D.

    SLEE

    VEO

    RPL

    UNG

    ER

    Hydraulic Cylinder Required Service Tools

  • 16 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Packing, wipers and bushings are considered normal maintenance or service items. These items are subject to contamination from external and internal foreign materials, many of which are abrasive in nature, causing abnormal wear or damage to the parts, to the extent that replacements are required.WARNING!!Before working on a telescopic cylinder mounted on a truck or trailer unit, use supports or holding devices that will absolutely prevent the body from accidentally lowering. Place control valve in the Lower position to assure that all pressure has been relieved from the cylinder. Because of our self-compensating Packing design, Standard Commercial HydraulicsCylinders require no packing adjustment. For Commercial Packing Assembly Installation Procedure see Service Repair Kit Page.Procedure for Adjusting Telescopic Cylinder Head Nuts.(For Cylinder designs using no Wave Springs and/or no U-Seals)1. Loosen set screw (or set screws) in head nut that holds in packing of leaking stage.2. Lightly tap head nut around circumference with a hammer.3. Back head nut off 1/2 to 1 full turn using a spanner or chain wrench. (Note: If stage rotates when head nut is turned, hold stage with a strap wrench.)4. Cycle cylinder 2 to 3 times to reset chevron vee packing.5. Retighten head nut approximately 1/2 turn further than it was when it was loosened.6. Tighten set screws.Procedure for Mis-Staging or Mis-Sequencing Cylinder.1. Loosen set screws in head nut that holds in packing which fi ts over stage that is sticking.2. Lightly tap head nut around circumference with a hammer.3. Back head nut off 1/2 turn using a spanner or chain wrench.4. Cycle cylinder, if cylinder still mis-stages, back head nut off another 1/2 turn.5. Cycle cylinder, if cylinder still mis-stages, tighten the head nut of the next stage that is extending.6. Tighten set screws.Bleeding Air from Single-Acting Telescopic Cylinders. For smooth operation of these cylinders, it is advisable to bleed the air from the cylinder weekly. Manual bleeding is accomplished by:1. Empty the dump body of any material.2. Remove the cover plate from the dog house of the dump body to access the bleeder valve.3. Fully extend the cylinder, raising the EMPTY dump bed.4. Lower the dump to within 1 foot from resting on the frame.5. With the fi ngers, turn the bleeder valve in a counterclockwise direction. This opens the valve and allows the air to escape from the cylinder.6. When a steady stream of oil comes from the bleeder, turn the valve in a clockwise direction until it is closed.

    If these procedures fail to correct the problem, please contact anAuthorized Service Center for Instructions.

    Normal Maintenance Items

  • 17 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Hydraulic Oil Recommendations

    All cylinder parts, with the exception of a few items, are lubricated by the hydraulic oil in the circuit. Particular attention must be paid to keep the oil in the circuit clean. Whenever there is a hydraulic component failure (cylinder, pump, valve), and there is a reason to feel that metal particles may be in the system, the oil must be drained, the entire system fl ushed clean, and any fi lter screens thoroughly cleaned or replaced. New oil should be supplied for the entire system. Oil suitable and recommended for use in circuits involving Commercial cylinders should meet the following specifi cations:

    These suggestions are intended as a guide only.Obtain your fi nal oil recommendations from your oil supplier.

    Viscosity Recommendations:Optimum operating viscosity is considered to be about 100 SSU.* 50 SSU minimum @ operating temperature 7500 SSU maximum @ starting temperature

    * 150 to 225 SSU @ 100o F. (37.8o C.) (generally) 44 to 48 SSU @ 210o F. (98.9o C.) (generally)

    Other Desirable Properties:Viscosity Index: 90 minimumAniline point: 175 minimum

    Additives Usually Recommended:Rust and Oxidation (R & O) InhibitorsFoam Depressant

    Other Desirable Characteristics:Stability of physical and chemical characteristics.High demulsibility (low emulsibility) for separation of water, air and contaminants.Resistant to the formation of gums, sludges, acids, tars and varnishes.High lubricity and fi lm strength.

    General Recommendations:A good quality hydraulic oil conforming to the characteristics listed above is essential to the satisfactory performance and long life of any hydraulic system.

    Oil should be changed on regular schedules in accordance with the manufactures recommendations and the system periodically fl ushed.

    Oil operating temperature should not exceed 200o F. (93o C.) with a maximum of 180o F. (82o C.) generally recom-mended. 120o F. to 140o F. (50o C. to 60o C.) is generally considered optimum. High temperatures result in rapid oil deterioration and may point out a need for an oil cooler or a larger reservoir. The nearer to optimum temperature, the longer the service life of the oil and the hydraulic components.

    Reservoir size should be large enough to hold and cool all the fl uid a system will need, yet it should not be waste-fully large. Minimum required capacity can vary anywhere between 1 and 3 times pump output. The reservoir must be able to hold all of the fl uid displaced by retracted cylinders when the system is not operating, yet provide space for expansion and foaming.

    Oil poured into the reservoir should pass through a 100 mesh screen. Pour only clean oil from clean containers into the reservoir.

    Approximate SSU at . . .

    Normal Temperatures:0o F. (-18o C.) to 100o F. (37.8o C.) ambient100o F. (37.8o C.) to 180o F. (82.2o C.) system

    Be sure the oil you use is recommended for the temperature you expect to encounter.

    OilGrade

    100OF.(37.8OC.)

    210O F.(98.9OC.)

    SAE 10 150 43SAE 20 330 51

    Never use Crank Case Drainings, Kerosene, Fuel Oil, or any Non-Lubricating Fluid, such as Water.

  • 18 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    1) Function Test Once the Cylinder is placed on the test stand and hydraulic lines attached, the cylinder will be cycled its full stroke a minimum of three (3) full cycles. The cylinder will be rejected if it functions erratically. Erratic function is excessive chatter, slapstrick, stalling and uncorrectable misstaging.

    2) Proof Pressure Test After the function test is performed the cylinder will be extended fully and pressure held for a minimum of thirty (30) seconds. This pressure will be 2500 psi or a pressure indicated on the assembly print. The cylinder will be rejected for external leakage or structural deformation. If the cylinder is double acting, it will be fully retracted and pressure held for a minimum of thirty (30) seconds. The pressure will be 2500 psi or a pressure indicated on the assembly print. The cylinder will be rejected for external leakage or structural deformation.

    3) Internal Bypass Test This test will be performed on all double acting cylinders and can be done in conjunction with the Proof Pressure Test. The cylinder will be fully extended and pressure held at 2500 psi. The retract line will be removed and piston seal bypass will be determined by the fl ow out of this cylinder port. Excessive bypass will be a cause for cylinder rejection. The cylinder will be fully retracted and pressure held at 2500 psi. The extend line will be removed and the piston bypass will be determined by the fl ow out of this cylinder port. The cylinder will be rejected for excessive fl ow. When making this test the hydraulic line should be completely removed from the cylinder port, and the open line from the valve should be plugged or capped since a slight back pressure in the tank return line would spill oil from the line if not plugged.

    Pass/Fail criteria if not noted on Assembly drawing is as follows: Cast Iron Rings Normal Maximum leakage 1 GPM. Bypass = 1/2 cubic inch per inch of bore diameter per minute. Extend bypass would be 1/2 cubic inch per inch of plunger piston ring OD per minute. Retract bypass would be 1/2 cubic inch per inch of piston ring OD per minute of each stage added together. Example SD73 Series; Extend bypass; 1/2 x 5.25 = 2.62 cubic in / min. Retract bypass; (1/2 x 7.25) + (1/2 x 6.25) + (1/2 x 5.25) = 9.38 cubic in / min.

    Soft Seals Maximum leakage 5 drops per minute.

    Standard Test Procedure for Hydraulic Cylinders

    Please NoteBefore Installing a New Cylinder in an old application

    Has the problem been corrected that caused the original cylinder to fail?Is the hydraulic fl uid clean of all contamination, water, and entrapped air?

    Are the hydraulic system relief valve pressures set and operating properly?Is the mechanism or unit the cylinder is operating in good mechanical condition?

  • 19 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Storage and Installation

    STORAGE

    It pays to keep spare hydraulic cylinders on hand for use when you need them. But, you must know and follow these recommended storage practices or the cylinders can be ruined. Hydraulic cylinders, though often large and unwieldy, are precision machines with fi nely fi nished parts and close tolerances. And theyre expensive. So handle them with care.

    For optimum storage life, hydraulic cylinders should be kept in an environment that is protected from excessive moisture and temperature extremes. A hot, dry dessert climate with cold nights, for example, must be accommodated when choosing the storage area. Daytime heat quickly bakes oil out of sealing materials, which causes leaks and rapid wear when the cylinder is placed in service. Cooling at night causes water condensation and corrosion damage to wear surfaces. Storage areas that allow exposure to rain, snow and extreme cold must like wise be avoided.

    Its best to store cylinders indoors if possible. But indoors or out, be sure that plugs or closures are properly installed in all ports to keep out moisture and dirt. However, overtightening of port plugs should be avoided. Widely varying temperatures and tightly closed ports may cause pressure inside the cylinder to build up to the point where the piston moves far enough to expose the rod to corrosion or contamination. Try to choose a storage location where the cylinders are protected from physical damage. Even a little ding from a falling bar or forklift tine can cause trouble later.

    Cylinders, Particularly large ones, should be stored closed in a vertical position with the rod end down. Be sure theyre blocked securely to keep them from toppling. Storing with the rod ends down keeps oil on the seals, which protects them from drying out. This is more critical with fabric and butyl seals than with urethane sealing ma-terials. Storing single-acting cylinders with the rod end up can cause port closures to pop open and leak, exposing the sleeves to corrosion damage and contamination. Storing with the rod end down also discourages the temptation to lift a cylinder by the rod eye a dangerous practice. If horizontal storage cannot be avoided, the rod or cylinder should be rolled into a new position every two months or so to prevent drying, distortion and deterioration of the seals. Dont forget that a cylinder can be a major source of contamination. A small scratch or nick on the sleeve will quickly shred packing and contaminate the system. Store cylinders carefully and keep them clean.

    The following procedures should be followed in order to prevent oxidation and maintain the surfaces of a mounted hydraulic cylinder during idle periods. These idle periods may include; inventory units, demo units, out of service units, etc.

    All machined surfaces left expose should be coated with a light fi lm of grease, if not oxidation will occur. If oxidation is present, apply a light coat of oil to the surfaces. Buff surfaces with 320 or 400 grit sandpaper. Do not buff surfaces up and down the length, buff only around the circumference. If after buffi ng, the surfaces show evidence of oxidation damage i.e., pitting, the cylinder should be inspected by an authorized service center for evaluation. Operation of a hydraulic cylinder with surface damage will shorten the longevity and preclude any warranty express or implied.

    INSTALLATION

    Cleanliness is an important consideration, and Parker cylinders are shipped with the ports plugged to protect them from contaminants entering the ports. These plugs should not be removed until the piping is to be installed. Before making the connection to the cylinder ports, the piping should be thoroughly cleaned to remove all chips or burrs which might have resulted from threading or fl aring operations. One small foreign particle can cause premature failure of the cylinder or other hydraulic system components. If oxidation is present, apply a light coat of oil to the surfaces. Proper alignment of the cylinder piston rod and its mating component on the machine should be checked in both the extended and retracted positions. Improper alignment will result in excessive rod gland and/or cylinder bore wear. Cylinders operating in an environment where air drying material are present such as fast- drying chemicals, paint, or welding splatter, or other hazardous conditions such as excessive heat, should have shields installed to prevent damage to the piston rod and piston rod seals.

  • 20 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Note: This guide is for use to determine approximate stroke and lifting requirements for a Front Mount Dump Body, they should not be used for Frameless Type Trailers, Underbody, Telescopic Farm (slant forward or rearward), or Scissor Type Hoists. Final dimensions and calculations should be determined by an engineering drawing.

    Front Mount Dump Body Stroke & Lifting Calculations

    B = Length in inchesCylinder base pin to body hinge pin

    "B"

    "D"Dump Angle

    "Stroke"

    SR

    Formula for Calculating the RequiredCylinder Stroke for a Dump Angle

    "B" X "D" = Approximate Stroke

    166" (B) X .845 (D) = 140" StrokeExample

    Normal minimum dump angle is 45 degreeNormal maximum dump angle id 57 degree

    Dump Angle Multipliers"D"

    .715

    .733

    .750

    .765

    .780

    .797

    .813

    .830

    .845

    .861

    .877

    .892

    .903

    .923

    .939

    .954

    Dump Angle

    42 deg43 deg44 deg45 deg46 deg47 deg48 deg49 deg50 deg51 deg52 deg53 deg54 deg55 deg56 deg57 deg

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    =

    SRSR

    A = Center of load to dump body hinge(in inches)

    Centerof Load

    "A"

    B = Length in inchesCylinder base pin to body hinge pin

    "B"

    Formula for Calculating Initial RequiredCylinder Force to Lift a Load

    Example50,000# X 85"

    166" =25,603# of force

    to start the lift

    Load (lbs) X "A""B" =

    Initial requiredcylinder force

    Commercial Telescopic Lifting CapacitiesStage O.D.in inches

    2.75"3.75"4.75"5.75"6.75"7.90"9.37"

    47528836

    1417620774286283921355165

    5940110451772125967357854901768956

    89091656726581389515367773525

    103434

    118792208935441519357157098034

    137911

    System operating pressure800 psi 1000 psi 1500 psi 2000 psi

    Note: For a good design, initial pressure should notexceed 800 psi at start of lift.Effective force (capacity)is only that of the sleeve / stage which is moving andwill decrease as cylinder changes to the next movingsleeve. The effective force will also be reduced if thecylinder is pushing at an angle.

  • 21 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Approximate Weights of MaterialsMaterial lbs. / cu. yd. tons / cu. yd. Material lbs. / cu. yd. tons / cu. yd.

    Andesite stone 4887 2.44 Earth & sand, wet 3240 1.62Ashes 1080 0.52 Fire Brick 3915 1.95Asphalt 2700 1.35 Fire Clay 3510 1.75

    Asphaltum 2349 1.17 Garbage 1150 0.57Basalt rock 4887 2.44 Gravel, dry 2970 1.48

    Brick, soft clay 2718 1.35 Gravel, out of water 1620 0.81Brick, hard clay 3397 1.69 Granite 4536 2.26Brick, pressed 3806 1.9 Lime, quick, loose 1431 0.71Brick, paving 4246 2.12 Lime, quick, shaken 1485 0.70Block, paving 3694 1.84 Limestone, solid 4536 2.26

    Bluestone 2970 1.48 Limestone, loose 2592 1.29Cement, natural 1512 0.75 Marble, solid 4455 2.22

    Cement, Portland 2430 1.21 Marble, loose 2592 1.29Cement, Portland, set 4941 2.47 Mortar, set 2781 1.39Cement, Rosendale 1863 0.93 Mud, dry 2430 1.21

    Cinders 1080 0.54 Mud, packed 3105 1.55Clay, dry 1701 0.85 Mud, wet 2916 1.45Clay, wet 2970 1.48 Pitch 1863 0.93

    Clay & gravel, dry 2700 1.35 Plaster of Paris 2646 1.32Coal, anthracite 1536 0.76 Powder, blasting 1682 0.84Coal, bituminous 1275 0.64 Quartz 4374 2.18

    Coke 837 0.42 Rubbish 199.8 0.09Concrete, cinders 2970 1.48 Sand, dry, loose 2619 1.30Concrete, gravel 4104 2.05 Sand, wet 3186 1.59

    Concrete, limestone 4050 2.02 Sandstone 4023 2.01Concrete, sandstone 3915 1.95 Slag, bank 1890 0.94Concrete, trap rock 4185 2.09 Slag, screenings 2700 1.35

    Crushed stone 2700 1.35 Slag, machine 2592 1.29Earth, dry, loose 1890 0.94 Slag, sand 1485 0.74

    Earth, damp, loose 2106 1.05 Shale 4374 2.18Earth, damp packed 2592 1.29 Slate 4725 2.31Earth & gravel, dry 2700 1.35 Tar 1674 0.83Earth & gravel, wet 3240 1.62 Tile 2970 1.43Earth & sand, dry 2709 1.35 Trap stone 5849 2.52

    Steel & Aluminum Gauge,Thickness and WeightSteel

    3/8" 0.375 15.320 lbs. per sq. ft.1/4" (approx. 3 Ga.) 0 250 10.200 lbs. per sq. ft.3/16" (approx. 7 Ga.) 0.188 7.650 lbs. per sq. ft.

    8 Ga. 0.164 6.875 lbs. per sq. ft.9 Ga. 0.149 6.250 lbs. per sq. ft.10 Ga. 0.134 5.625 lbs. per sq. ft.11 Ga. 0.120 5.000 lbs. per sq. ft.12 Ga. 0.105 4.375 lbs. per sq. ft.13 Ga. 0.090 3.750 lbs. per sq. ft.14 Ga. 0.075 3.125 lbs. per sq. ft.

    Aluminum3/8" 0.375 5.18 lbs. per sq. ft.1/4" 0.250 3.53 lbs. per sq. ft.

    3/16" 0.188 2.65 lbs. per sq. ft.5/32" 0.156 2.25 lbs. per sq. ft.

    Commodities & Materials Approximate Weights

  • 22 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    SINGLE STAGE SCISSORUNDERBODY TELESCOPICSLANT FORWARD OR SLANT REARWARD

    UNDER BODY ARM HOIST

    UNDER BODY ARM - SCISSOR LOST MOTION SCISSOR

    UNDER BODY DIRECT LIFT

    FRONT MOUNT TELESCOPICHEAD LIFT OR BOTTOM LIFT

    TELESCOPIC SCISSORHINGE FORWARD OR REARWARD

    Dump Hoist Type Identifi cation Chart

  • 23 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Dump Trailer Type Identifi cation Chart

    FRAME TYPE

    FRAMELESS

    FRAMELESS HYBRID

  • 24 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    ClosedStroke OpenCBAE

    N O PQ

    H"B" or "C" Type Mount"C" or "D" Type Mount

    G Dia.D Dia.

    Note; Diameters D and G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    Single-Acting Telescopic Cylinders With CC, DB, and DC Mounts

    ENGINEERING 10 DIGIT NOMINAL NUMBER A B C D E G HNUMBER NUMBER STAGE OD STAGES STROKE CLOSED OPEN PIN WIDTH PIN WIDTHS42CC-19-40 3771012052 4 2 40.00 32.44 72.44 1.50 2.00 1.50 2.00

    S43DB-3-75 3781013005 4 3 75.00 33.88 108.88 2.00 5.00 1.25 1.69

    S52CC-41-54.62 3771512092 5 2 54.62 38.00 92.62 2.50 3.62 2.50 3.62S52CC-41-67.25 3771512091 5 2 67.25 46.81 114.06 2.50 3.62 2.50 3.62S52DB-9-67.50 3771512080 5 2 67.50 46.75 114.25 3.00 5.50 2.00 3.00

    S53DB-13-60 3781513005 5 3 60.00 30.00 90.00 2.00 6.00 1.50 2.63S53DB-18-90 3781513008 5 3 90.00 39.75 129.75 2.00 6.00 1.50 2.63S53DC-65-104 3771513168 5 3 104.00 47.69 151.69 2.00 7.00 1.75 2.00S53DC-65-107 3771513169 5 3 107.56 48.38 155.94 2.00 7.00 1.75 2.00S53DC-65-120 3771513166 5 3 120.13 53.06 173.19 2.00 7.00 1.75 2.00S53DC-65-126 3771513170 5 3 126.63 54.56 181.19 2.00 7.00 1.75 2.00S53DC-66-72 3771513172 5 3 72.00 37.19 109.19 2.00 7.00 1.63 1.50S53DC-66-84 3771513171 5 3 84.00 41.19 125.19 2.00 7.00 1.63 1.50S53DC-68-105 3771513176 5 3 105.00 48.50 153.50 2.00 7.75 1.75 1.50S53DC-68-120 3771513177 5 3 120.00 52.50 172.50 2.00 7.75 1.75 1.50S53DC-68-123 3771513178 5 3 123.00 54.50 177.50 2.00 7.75 1.75 1.50S53DC-68-99 3771513175 5 3 99.00 46.50 145.50 2.00 7.75 1.75 1.50

    S63DC-101-104 3771413319 6 3 103.94 47.00 150.94 2.00 7.00 2.00 2.00S63DC-101-107 3771413320 6 3 107.56 48.38 155.94 2.00 7.00 2.00 2.00S63DC-101-120 3771413321 6 3 120.06 52.62 172.68 2.00 7.00 2.00 2.00S63DC-101-126 3771413322 6 3 126.31 54.56 180.87 2.00 7.00 2.00 2.00S63DC-101-140 3771413324 6 3 140.25 59.81 200.06 2.00 7.00 2.00 2.00S63DC-101-150 3771413318 6 3 149.88 63.00 212.88 2.00 7.00 2.00 2.00S63DC-101-86 3771413316 6 3 86.75 40.88 127.63 2.00 7.00 2.00 2.00S63DC-101-92 3771413317 6 3 92.00 45.00 137.00 2.00 7.00 2.00 2.00S63DC-102-120 3771413325 6 3 120.00 53.50 173.50 2.38 8.00 2.19 1.50S63DC-102-126 3771413326 6 3 126.00 55.50 181.50 2.38 8.00 2.19 1.50S63DC-102-138 3771413327 6 3 138.00 59.50 197.50 2.38 8.00 2.19 1.50S63DC-102-150 3771413328 6 3 150.00 66.00 216.00 2.38 8.00 2.19 1.50S63DC-102-162 3771413329 6 3 162.00 67.50 229.50 2.38 8.00 2.19 1.50S63DC-79-67 3771413260 5 3 67.00 36.50 103.50 3.00 7.88 1.75 1.50S63DC-96-130 3771413308 6 3 130.00 56.00 186.00 2.00 7.00 2.00 2.00S63DC-96-82.50 3771413306 6 3 82.50 43.56 126.06 2.00 7.00 2.00 2.00S63DC-97-111 3771413309 6 3 111.00 49.94 160.94 2.00 7.00 2.00 2.00S63DC-97-123 3771413310 6 3 123.00 54.94 177.94 2.00 7.00 2.00 2.00

  • 25 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Single-Acting Telescopic Cylinders With CC, DB, and DC Mounts

    ClosedStroke OpenCBAE

    N O PQ

    H"B" or "C" Type Mount"C" or "D" Type Mount

    G Dia.D Dia.

    10 DIGIT N O P Q GALS TO GALS TO WEIGHT REBUILD REPACKNUMBER LOCATION SIZE LOCATION SIZE FILL EXTEND LBS KIT KIT

    3771012052 14" 1/2" NPT 2.07 2.46 52 3751805175 3751805174

    3781013005 19" 1/2" NPT 0.77 2.11 85 3751805720 3751804368

    3771512092 3.88" #8 SAE 2 3.4 120 3751805581 37518055803771512091 3.88" #8 SAE 2.51 4.17 145 3751805581 37518055803771512080 20" #12 SAE 2.42 4.2 135 3751805581 3751805580

    3781513005 19" 1/2" NPT 1.7 3 120 3751804017 39118040203781513008 19" 3/4" NPT 1.22 4.45 200 3751804017 39118040203771513168 15.50" 1" NPT 2.4 5.89 175 3751804017 39118040203771513169 9.94" 1" NPT 2.4 5.89 178 3751804017 39118040203771513166 15.50" 1" NPT 2.42 5.9 195 3751804017 39118040203771513170 16.12" 1" NPT 2.42 5.9 205 3751804017 39118040203771513172 19.50" 3/4" NPT 1.8 3.5 165 3751804017 39118040203771513171 19.50" 3/4" NPT 1.8 3.5 170 3751804017 39118040203771513176 24.81" #16 90D SAE 2 5.2 170 3751804017 39118040203771513177 24.81" #16 90D SAE 1.62 5.9 220 3751804017 39118040203771513178 24.81" #16 90D SAE 2.8 6.1 232 3751804017 39118040203771513175 24.81" #16 90D SAE 1.95 4.87 165 3751804017 3911804020

    3771413319 20.81" 1" NPT 1.75 8.05 250 3751804018 39118041093771413320 20.81" 1" NPT 1.82 8.37 256 3751804018 39118041093771413321 20.81" 1" NPT 2.03 9.33 275 3751804018 39118041093771413322 20.81" 1" NPT 2.13 9.84 285 3751804018 39118041093771413324 20.81" 1" NPT 2.37 10.94 310 3751804018 39118041093771413318 20.81" 1" NPT 2.53 11.71 325 3751804018 39118041093771413316 20.81" 1" NPT 1.47 6.79 225 3751804018 39118041093771413317 20.81" 1" NPT 1.56 7.14 195 3751804018 39118041093771413325 24.91" #16 90D SAE 2.02 9.4 270 3751804018 39118041093771413326 24.91" #16 90D SAE 2.13 9.9 275 3751804018 39118041093771413327 24.91" #16 90D SAE 2.33 11.1 300 3751804018 39118041093771413328 24.91" #16 90D SAE 2.54 11.9 330 3751804018 39118041093771413329 24.91" #16 90D SAE 2.75 12.64 330 3751804018 39118041093771413260 20.50" 3/4" NPT 2.18 5.12 180 3751805654 37518055943771413308 20.81" 1" 90D NPT 2.15 10.85 295 3751804018 39118041093771413306 20.81" 1" 90D NPT 2.15 10.85 230 3751804018 39118041093771413309 3.81" 1" NPT 24" 1" NPT 1.87 8.61 270 3751804018 39118041093771413310 3.81" 1" NPT 29" 1" NPT 2.08 9.63 285 3751804018 3911804109

    Note; Diameters D and G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

  • 26 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    ClosedStroke OpenCBAE

    N O PQ

    H"B" or "C" Type Mount"C" or "D" Type Mount

    G Dia.D Dia.

    Single-Acting Telescopic Cylinders With CC, DB, and DC Mounts

    Note; Diameters D and G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    ENGINEERING 10 DIGIT NOMINAL NUMBER A B C D E G HNUMBER NUMBER STAGE OD STAGES STROKE CLOSED OPEN PIN WIDTH PIN WIDTHS64DB-12-135 3771414058 6 4 135.00 47.19 182.19 1.75 8.00 1.50 2.69S64DB-12-156 3771414056 6 4 156.00 53.19 209.19 1.75 8.00 1.50 2.69S64DC-14-156 3771414059 6 4 156.00 53.62 209.62 2.00 7.25 2.00 1.75S64DC-15-157 3771414061 6 4 157.00 58.56 215.56 1.50 7.00 1.50 2.00

    S73DC-66-110 3772513127 7 3 110.63 50.06 160.69 2.00 8.25 2.00 2.00S73DC-66-120 3772513132 7 3 120.00 53.12 173.12 2.00 8.25 2.00 2.00S73DC-66-124 3772513128 7 3 124.88 54.81 179.69 2.00 8.25 2.00 2.00S73DC-66-129 3772513135 7 3 129.00 56.50 185.50 2.00 8.25 2.00 2.00S73DC-66-140 3772513129 7 3 140.44 60.00 200.44 2.00 8.25 2.00 2.00S73DC-66-150 3772513131 7 3 150.00 63.50 213.50 2.00 8.25 2.00 2.00

    S74DC-74-120 3772514124 7 4 120.00 44.12 164.12 2.00 8.25 2.00 2.00S74DC-74-135 3772514125 7 4 135.00 48.44 183.44 2.00 8.25 2.00 2.00S74DC-74-140 3772514122 7 4 140.00 49.75 189.75 2.00 8.25 2.00 2.00S74DC-74-156 3772514123 7 4 156.00 53.75 209.75 2.00 8.25 2.00 2.00S74DC-74-161 3772514120 7 4 161.75 55.31 217.06 2.00 8.25 2.00 2.00S74DC-74-180 3772514126 7 4 180.00 61.12 241.12 2.00 8.25 2.00 2.00

    S84DC-40-170 3772914050 8 4 170.00 57.25 227.25 2.00 9.50 2.00 2.00S84DC-66-140 3772914080 8 4 140.00 49.75 189.75 2.00 9.50 2.00 2.00S84DC-66-148 3772914081 8 4 147.75 51.50 199.25 2.00 9.50 2.00 2.00S84DC-66-156 3772914086 8 4 156.00 53.75 209.75 2.00 9.50 2.00 2.00S84DC-66-161 3772914082 8 4 160.00 55.75 215.75 2.00 9.50 2.00 2.00S84DC-66-170 3772914083 8 4 170.00 57.25 227.25 2.00 9.50 2.00 2.00S84DC-66-180 3772914084 8 4 180.00 59.75 239.75 2.00 9.50 2.00 2.00S84DC-66-188 3772914085 8 4 188.00 61.75 249.75 2.00 9.50 2.00 2.00

    S85DC-66-170 3772915164 8 5 170.00 49.88 219.88 2.00 9.50 2.00 2.00S85DC-66-190 3772915166 8 5 189.00 54.62 243.62 2.00 9.50 2.00 2.00S85DC-66-197 3772915162 8 5 196.13 55.25 251.38 2.00 9.50 2.00 2.00S85DC-66-220 3772915167 8 5 219.00 60.00 279.00 2.00 9.50 2.00 2.00S85DC-66-235 3772915161 8 5 234.00 64.62 298.62 2.00 9.50 2.00 2.00S85DC-66-250 3772915160 8 5 249.00 68.62 317.62 2.00 9.50 2.00 2.00S85DC-66-265 3772915165 8 5 265.00 71.00 336.00 2.00 9.50 2.00 2.00S85DC-66-285 3772915163 8 5 285.00 78.50 363.50 2.00 9.50 2.00 2.00

  • 27 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Single-Acting Telescopic Cylinders With CC, DB, and DC Mounts

    ClosedStroke OpenCBAE

    N O PQ

    H"B" or "C" Type Mount"C" or "D" Type Mount

    G Dia.D Dia.

    Note; Diameters D and G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    10 DIGIT N O P Q GALS TO GALS TO WEIGHT REBUILD REPACKNUMBER LOCATION SIZE LOCATION SIZE FILL EXTEND LBS KIT KIT

    3771414058 5.50" 2, 3/4" NPT 2.6 8.1 275 3751804021 39118042373771414056 5.50" 2, 3/4" NPT 3.2 10.1 293 3751804021 39118042373771414059 6.31" 1" NPT 2.5 10.01 310 3751804021 39118042373771414061 4.31" 1" NPT 3.8 9.5 310 3751804021 3911804237

    3772513127 7.06" 1" NPT 4.62" 1" NPT 2.34 12.6 335 3751804019 37518040023772513132 7.06" 1" NPT 4.62" 1" NPT 2.4 13.5 360 3751804019 37518040023772513128 7.06" 1" NPT 4.62" 1" NPT 2.53 14.2 370 3751804019 37518040023772513135 8.56" 1" NPT 4.62" 1" NPT 2.6 14.7 385 3751804019 37518040023772513129 7.06" 1" NPT 4.62" 1" NPT 2.84 16.1 400 3751804019 37518040023772513131 7.06" 1" NPT 4.62" 1" NPT 3.1 17.1 420 3751804019 3751804002

    3772514124 7.06" 1" NPT 4.62" 1" NPT 2.2 11.5 325 3751804022 37518040033772514125 7.06" 1" NPT 4.62" 1" NPT 2.5 13 375 3751804022 37518040033772514122 7.06" 1" NPT 4.62" 1" NPT 2.6 13.5 365 3751804022 37518040033772514123 7.06" 1" NPT 4.62" 1" NPT 2.9 15.1 388 3751804022 37518040033772514120 7.06" 1" NPT 4.62" 1" NPT 4.48 15.5 405 3751804022 37518040033772514126 7.06" 1" NPT 4.62" 1" NPT 3.5 17.4 430 3751804022 3751804003

    3772914050 6.50" 1" NPT 5.62" 1" NPT 7.6 23.3 570 3751804023 39118040543772914080 6.50" 1" NPT 5.62" 1" NPT 3 19.1 488 3751804023 39118040543772914081 6.50" 1" NPT 5.62" 1" NPT 3.2 20.2 515 3751804023 39118040543772914086 5.56" 1" NPT 5.62" 1" NPT 3.4 21.3 535 3751804023 39118040543772914082 6.50" 1" NPT 5.62" 1" NPT 3.5 22 555 3751804023 39118040543772914083 6.50" 1" NPT 5.62" 1" NPT 3.7 23.4 568 3751804023 39118040543772914084 6.50" 1" NPT 5.62" 1" NPT 3.9 24.7 591 3751804023 39118040543772914085 6.50" 1" NPT 5.62" 1" NPT 4.1 25.8 610 3751804023 3911804054

    3772915164 6.50" 1" NPT 5.62" 1" NPT 3.4 20 516 3751804024 39118040603772915166 6.50" 1" NPT 5.62" 1" NPT 3.8 22.3 555 3751804024 39118040603772915162 6.50" 1" NPT 5.62" 1" NPT 3.9 23.1 560 3751804024 39118040603772915167 6.50" 1" NPT 5.62" 1" NPT 4.4 25.9 565 3751804024 39118040603772915161 6.50" 1" NPT 5.62" 1" NPT 4.7 27.7 650 3751804024 39118040603772915160 6.50" 1" NPT 5.62" 1" NPT 5 29.5 685 3751804024 39118040603772915165 6.50" 1" NPT 5.62" 1" NPT 5.3 31.5 715 3751804024 39118040603772915163 6.50" 1" NPT 5.62" 1" NPT 5.7 34 795 3751804024 3911804060

  • 28 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Single-Acting Telescopic Cylinders With CC, DB, and DC Mounts

    ClosedStroke OpenCBAE

    N O PQ

    H"B" or "C" Type Mount"C" or "D" Type Mount

    G Dia.D Dia.

    Note; Diameters D and G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    ENGINEERING 10 DIGIT NOMINAL NUMBER A B C D E G HNUMBER NUMBER STAGE OD STAGES STROKE CLOSED OPEN PIN WIDTH PIN WIDTHS95DC-52-190 3773115068 9 5 190.00 56.00 246.00 2.00 10.88 2.00 2.00S95DC-52-220 3773115064 9 5 218.00 62.44 280.44 2.00 10.88 2.00 2.00S95DC-52-235 3773115063 9 5 233.00 65.44 298.44 2.00 10.88 2.00 2.00S95DC-52-250 3773115061 9 5 248.00 68.44 316.44 2.00 10.88 2.00 2.00S95DC-52-265 3773115069 9 5 265.00 72.62 337.62 2.00 10.88 2.00 2.00S95DC-52-280 3773115067 9 5 280.00 78.62 358.62 2.00 10.88 2.00 2.00S95DC-52-300 3773115066 9 5 300.00 79.00 379.00 2.00 10.88 2.00 2.00S95DC-52-320 3773115065 9 5 320.00 83.00 403.00 2.00 10.88 2.00 2.00S95DC-52-340 3773115062 9 5 340.00 87.00 427.00 2.00 10.88 2.00 2.00

  • 29 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Single-Acting Telescopic Cylinders With CC, DB, and DC Mounts

    ClosedStroke OpenCBAE

    N O PQ

    H"B" or "C" Type Mount"C" or "D" Type Mount

    G Dia.D Dia.

    Note; Diameters D and G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    10 DIGIT N O P Q GALS TO GALS TO WEIGHT REBUILD REPACKNUMBER LOCATION SIZE LOCATION SIZE FILL EXTEND LBS KIT KIT

    3773115068 6.50" 1" NPT 5.75" 1" NPT 3.9 22.4 835 3751804025 37518040043773115064 6.50" 1" NPT 5.75" 1" NPT 6.8 36.2 855 3751804025 37518040043773115063 6.50" 1" NPT 5.75" 1" NPT 7.1 38.7 880 3751804025 37518040043773115061 6.50" 1" NPT 5.75" 1" NPT 7.5 41.3 1100 3751804025 37518040043773115069 6.50" 1" NPT 5.75" 1" NPT 8.2 44.6 1200 3751804025 37518040043773115067 6.50" 1" NPT 5.75" 1" NPT 9.3 47.6 1215 3751804025 37518040043773115066 6.50" 1" NPT 5.75" 1" NPT 9.6 50.2 1230 3751804025 37518040043773115065 6.50" 1" NPT 5.75" 1" NPT 9.8 54.1 1200 3751804025 37518040043773115062 12.50" 1" NPT 5.75" 1" NPT 10.2 59.9 1245 3751804025 3751804004

  • 30 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    ClosedStroke OpenCBA

    J

    NOS

    KM

    L

    H"B" or C Type Mount" ""M" Type Mount

    G Dia.R

    Single-Acting Telescopic Cylinders With MB and MC Mounts

    Note; Bold / Highlighted Items are Standard Warehouse Items.Note; Diameters G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    ENGINEERING 10 DIGIT NOMINAL NUMBER A B C G H J K L MNUMBER NUMBER STAGE OD STAGES STROKE CLOSED OPEN PIN WIDTH TR to PIN WIDTH DIA. LGTHS63MB-8-140 3771413124 6 3 140.25 61.62 201.9 1.5 3.62 14.37 12.38 1.8 1.69

    S74MB-3-154 3772514058 7 4 154 55.62 209.6 1.5 3.62 14.37 12.25 1.8 1.63S74MB-3-172 3772514062 7 4 172 58.34 230.3 1.5 3.62 14.37 12.25 1.8 1.63

    S85MC-48-200 3772915121 8 5 199 55 254 2 3 15.5 14 2.3 1.25S85MC-48-220 3772915122 8 5 219 59 278 2 3 15.5 14 2.3 1.25S85MC-48-235 3772915123 8 5 234 65 299 2 3 15.5 14 2.3 1.25S85MC-48-250 3772915120 8 5 249 67 316 2 3 15.5 14 2.3 1.25S85MC-48-265 3772915119 8 5 265 71 336 2 3 15.5 14 2.3 1.25S85MC-48-280 3772915118 8 5 280 78.87 358.9 2 3 15.5 14 2.3 1.25

  • 31 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Single-Acting Telescopic Cylinders With MB and MC Mounts

    ClosedStroke OpenCBA

    J

    NOS

    KM

    L

    H"B" or C Type Mount" ""M" Type Mount

    G Dia.R

    Note; Bold / Highlighted Items are Standard Warehouse Items.Note; Diameters G are for nominal pin size, for actual hole size refer to print.Note; Nominal Stage OD, refers to the Largest Moving Sleeve.

    10 DIGIT N O R S GALS TO GALS TO WEIGHT REBUILD REPACKNUMBER LOCATION SIZE LOCATION SIZE FILL EXTEND LBS KIT KIT3771413124 2" 1" NPT 4.8 11.2 280 3751804018 3911804109

    3772514058 2" 1" NPT 5.2 15.1 412 3751804022 37518040033772514062 2" 1" NPT 5.6 16.6 436 3751804022 3751804003

    3772915121 2" 1" NPT 6.4 23.5 620 3751804024 39118040603772915122 2" 1" NPT 7.1 26.1 640 3751804024 39118040603772915123 2" 1" NPT 7.8 27.2 670 3751804024 39118040603772915120 2" 1" NPT 8.4 29.1 720 3751804024 39118040603772915119 2" 1" NPT 8.7 31.6 780 3751804024 39118040603772915118 2" 1" NPT 9.8 34.1 800 3751804024 3911804060

  • 32 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    AccurateHH-1 ...........................D62LB-5-80HH-2 ...........................D72LB-9-80HP-HH001 ..................D62LB-5-80HP-HH002 ..................D72LB-9-80MF-51 .........................D72LB-9-80

    Anthony Midwest BodyH070105 .....................S63DC-97-111 CM26H0701052 ...................S63DC-97-111 CM26H0710432 ...................S73DC-66-110 CM26H075018 .....................S73DC-66-124 CM23H0750182 ...................S73DC-66-124 CM26H130409 ...................... S63DC-101-140 CM26

    BeallA3602 .........................S53DC-65-126A3660 .........................S63DC-101-140

    Benton HarborA89646 .......................D70LN-5-90P89645 .......................D70LN-5-80P89648 .......................D60DB-23-72

    Bme Engineering CoP-60-OR-176T Hoist ...SD63CB-23-118

    Caterpillar246-7145 ....................S84DC-66-140246-7332 ....................S63MB-8-140246-7359 ....................S85MC-48-250246-7444 ....................S73DC-66-140246-7456 ....................S74DC-74-156246-7564 ....................S63DC-97-123246-7594 ....................S64DB-12-135

    Commercial / Parker3782000014................3782000014B4079 .........................D35LD-7-16B4100 .........................D25LD-2-90B4103 .........................D45CC-19-41.50B4388 .........................D20DD-8-95B4777 .........................D30CD-13-28B5109 .........................D40CB-10-42B5162 .........................D30CC-17-28.19B5420 .........................D62LB-5-80B5429 .........................D20DD-6-6.25B5489 .........................D50DD-28-39.50B5501 .........................D35DD-7-17.88B5546 .........................D25LL-14-42B5548 .........................D40CL-13-45.38B5550 .........................D45LD-7-45.38B5551 .........................D35LD-5-19B5609 .........................D40MD-1-72B5642 .........................D30LD-10-36B5653 .........................D30CC-19-16.00B5654 .........................D30CC-20-8.00B5655 .........................D30CC-18-8.00B5788 .........................D45CC-20-46B5790 .........................D25LL-15-84B5799 .........................D17AE-2-71.88B5845 .........................D70DD-9-79B5866 .........................D30CE-11-18.50B5873 .........................D50CC-25-43B5947 .........................D40DD-19-22.50B6044 .........................B6044B6148 .........................D35CC-28-38B6151 .........................D20DD-8-95B6231 .........................D45DD-10-52.75C3805 .........................D50CB-8-27C3810 .........................D60CD-5-34C3814 .........................D60CD-5-34C3865 .........................D40DB-7-28.5C3870 .........................D60DC-12-42.62C3872 .........................D50CC-27-36C3878 .........................D55CC-10-24.25C3880 .........................D60DD-20-79C3881 .........................D70DD-9-79C3882 .........................D60CF-3-32.38

    Commercial / Parker C3884 .........................S41LC-1-39.38C3919 .........................D45CD-5-49.12C3926 .........................D40CD-8-22C4101 .........................D40CD-14-25C4208 .........................D32LL-11-38C4435 .........................D30LD-8-33.38C4444 .........................D60DB-23-72C4497 .........................D32LL-11-38C4622 .........................D45CC-19-41.50C4774 .........................D65CC-9-66C4793 .........................D55CC-6-63C5220 .........................D32LL-11-38D20DD-4-6.25 ............D20DD-6-6.25D20DD-6-6.25 ............D20DD-6-6.25D30CD-10-28 .............D30CD-13-28D30LD-2-33.38 ...........D30LD-8-33.38D30LD-7-33.38 ...........D30LD-8-33.38D35CC-16-26 .............D35CC-27-26D35DD-1-17.88 ..........D35DD-7-17.88D35LC-2-2.00 .............3782000014D4094 .........................D60BC-5-30.31 495D40CB-7-42 ................D40CB-10-42D40CD-16-29.50 ........D40CD-16-29.50D40CD-8-22 ...............D40CD-8-22D40CL-2-39.38 ...........S41LC-1-39.38D40DB-3-25.62 ...........D40DB-7-25.62D40DB-3-28.5 .............D40DB-7-28.5D40DB-4-25.62 ...........D40DB-7-25.62D40DB-6-25.62 ...........D40DB-7-25.62D40DB-6-28.5 .............D40DB-7-28.5D40LD-3-24.75 ...........D40LD-10-24.75D40LD-5-24.75 ...........D40LD-11-24.75D40MD-1-72 ...............D40MD-1-72D4145 .........................SD53CC-48-164D4171 .........................D55DD-14-38.62D4172 .........................D50DD-29-25.62D4190 .........................S31CB-2-42D4210 .........................D60DC-13-65.75D4265 .........................D50DD-30-32.50D4266 .........................D45DD-9-23D4398 .........................D35CC-27-26D4434 .........................D45CD-5-49.12D4482 .........................D55CC-12-49.12D4496 .........................D45CC-20-46D4541 .........................D50DD-32-37.25D45CC-15-41.50 ........D45CC-19-41.50D45CD-1-49.13 ..........D45CD-5-49.12D45CD-2-49.12 ..........D45CD-4-49.12D45CD-3-49.12 ..........D45CD-5-49.12D50DD-24-39.50 ........D50DD-28-39.50D55CC-1-49.13 ..........D55CC-12-49.12D55CC-3-49.13 ..........D55CC-12-49.12D60BC-2-30.31 ...........D60BC-5-30.31D60BC-3-30.31 ...........D60BC-5-30.31D60BC-4-30.31 ...........D60BC-5-30.31D60BC-5-30.31 ...........D60BC-5-30.31D60DB-4-72 ................D60DB-23-72D60DB-7-72 ................D60DB-23-72D60DC-10-30.50 ........D60BC-5-30.31 495D60DC-11-30.50 ........D60BC-5-30.31 536D60DC-1-42.62 ..........D60DC-12-42.62D60DC-7-42.62 ..........D60DC-12-42.62D60DD-11-79 .............D60DD-20-79D60DD-14-79 .............D60DD-20-79D60DD-16-79 .............D60DD-20-79D60DD-20-79 .............D60DD-20-79D62DB-7-72 ................D60DB-23-72D62DC-10-30 .............D60BC-5-30.31 495D62LB-2-81 ................D62LB-5-80D62LB-3-79 ................D62LB-5-80D62LB-3-80 ................D62LB-5-80D62LB-4-80 ................D62LB-5-80D62LB-5-80 ................D62LB-5-80D62MT-2-80 ................D62LB-5-80D65CC-10-66 .............D65CC-9-66D70DD-5-79 ...............D70DD-9-79D70DD-6-79 ...............D70DD-9-79D70DD-9-79 ...............D70DD-9-79

    Commercial / Parker D70LN-1-80 ................D70LN-5-80D70LN-2-80 ................D70LN-5-80D70LN-2-90 ................D70LN-5-90D70LN-4-80 ................D70LN-5-80D72DB-10-79 ..............D70DD-9-79D72DB-3-25 ................D72DB-7-25D72DB-4-25 ................D72DB-7-25D72DB-7G-25 .............D72DB-7-25D72LB-1-80 ................D72LB-9-80D72LB-3-80 ................D72LB-9-80D72LB-5-80 ................D72LB-9-80D72LB-6-81 ................D72LB-9-80D72LB-8-80 ................D72LB-9-80D72LP-1-80 ................D70LN-5-80D72MI-1-80 .................D72LB-9-80D72MT-1-80 ................D72LB-9-80D84DA-1-25 ................D84DB-7-25D84DB-3-25 ................D84DB-7-25D84DB-4-25 ................D84DB-7-25D84DB-4-25-1 ............D84DB-7-25-1D84DB-5-25 ................D84DB-7-25D84DB-5-25-1 ............D84DB-7-25-1D84DB-7G-25 .............D84DB-7-25D84DB-7G-25-1 ..........D84DB-7-25-1S32DB-1-43 ................S32DB-3-42.62S32DB-1-43 CM72 .....S32DB-3-42.62 CM72S32DB-1-50 ................S32DB-3-50S32DB-1-50 CM72 .....S32DB-3-50 CM72S41CL-2-39.38 ...........S41LC-1-39.38S42CC-12-40 ..............S42CC-19-40S42DB-5-43 ................S42DB-8-43S42DB-5-43 CM72 .....S42DB-8-43 CM72S42DB-5-51 ................S42DB-8-51S42DB-5-51 CM72 .....S42DB-8-51 CM72S42MB-1-82 ...............S42MB-3-90S42MB-1-83 ...............S42MB-3-90S42MB-1-86 ...............S42MB-3-90S42MB-1-90 ...............S42MB-3-90S42MB-3-83 ...............S42MB-3-90S43DB-2-75 ................S43DB-3-75S43DB-4-75 ................S43DB-3-75S52CC-34-54.62 .........S52CC-41-54.62S52CC-34-67.25 .........S52CC-41-67.25S52CC-37-54.62 .........S52CC-41-54.62S52CC-38-67.25 .........S52CC-41-67.25S52DB-11-67.50 .........S52DB-9-67.50S53DB-1-103 ..............S53DB-20-103S53DB-13-90 ..............S53DB-18-90S53DB-18-60 ..............S53DB-13-60S53DB-3-75 ................S53DC-66-72 CM25S53DB-8-103 ..............S53DB-20-103S53DC-10-72 ..............S53DC-66-72S53DC-10-84 ..............S53DC-66-84S53DC-11-104 ............S53DC-65-104S53DC-11-107 ............S53DC-65-107S53DC-11-120 ............S53DC-65-120S53DC-11-126 ............S53DC-65-126S53DC-11-130 ............S53DC-65-130S53DC-11G-107 .........S53DC-65-107S53DC-11G-126 .........S53DC-65-126S53DC-12-104 ............S53DC-65-104S53DC-12-120 ............S53DC-65-120S53DC-12-130 ............S53DC-65-130S53DC-12-84 ..............S53DC-66-84 CM8S53DC-14-72 ..............S53DC-66-72S53DC-14-84 ..............S53DC-66-84S53DC-14G-72 ...........S53DC-66-72S53DC-14G-84 ...........S53DC-66-84S53DC-15-105 ............S53DC-68-105S53DC-15-120 ............S53DC-68-120S53DC-15-123 ............S53DC-68-123S53DC-15-99 ..............S53DC-68-99S53DC-15G-105 .........S53DC-68-105S53DC-15G-120 .........S53DC-68-120S53DC-15G-123 .........S53DC-68-123S53DC-15G-99 ...........S53DC-68-99S53DC-19-90 ..............S53DB-12-90S53DC-3-72 ................S53DC-66-72

    Crossover and Application Data is for Reference Purpose Only. No Other Conditions are Expressed or Implied.Note: It is the Users Responsibility to Verify if the Replacement Cylinder is Interchangeable.Note: In some applications, modifi cations may be required for proper cylinder installation.

    Quick Reference Guide

  • 33 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Commercial / Parker S53DC-3-84 ................S53DC-66-84S53DC-4-107 ..............S53DC-65-107S53DC-4-126 ..............S53DC-65-126S53DC-5-107 ..............S53DC-65-107S53DC-5-126 ..............S53DC-65-126S53DC-60-81 ..............S53DC-60-81S53DC-6-105 ..............S53DC-68-105S53DC-6-120 ..............S53DC-68-120S53DC-6-123 ..............S53DC-68-123S53DC-65-104 ............S53DC-65-104S53DC-6-99 ................S53DC-68-99S53DC-8-104 ..............S53DC-65-104S53DC-8-120 ..............S53DC-65-120S53DC-8-130 ..............S53DC-65-130S53DC-8-84 ................S53DC-66-84 CM8S53DC-9-72 ................S53DC-66-72S53DC-9-84 ................S53DC-66-84S53MB-1-120 .............S53MB-3-120S53MB-3-120 .............S53MB-3-120S53MB-5-90 ...............S53MB-5-90S62CC-15-69 ..............S62CC-32-69S62CC-30-69 ..............S62CC-32-69S63CC-22-111 ............S63DC-97-111S63CC-22-123 ............S63DC-97-123S63CC-22-80 ..............S63DC-101-77S63DC-101-130 ..........S63DC-96-130S63DC-101-82.50 .......S63DC-96-82.50S63DC-22-111 ............S63DC-97-111S63DC-22-123 ............S63DC-97-123S63DC-22-80 ..............S63DC-101-77S63DC-22-87 ..............S63DC-101-92S63DC-22-90 ..............S63DC-101-92S63DC-22-95 ..............S63DC-101-104S63DC-23-108 ............S63DC-97-111S63DC-23-128 ............S63DC-96-130S63DC-26-111 ............S63DC-97-111S63DC-27-111 ............S63DC-97-111 CM9S63DC-28-120 ............ S63DC-101-120 CM45S63DC-30-111 ............S63DC-97-111S63DC-30-123 ............S63DC-97-123S63DC-31-107 ............ S63DC-101-107 CM37S63DC-3-111 ..............S63DC-97-111S63DC-31-126 ............S63DC-97-123 CM37S63DC-32-120 ............S63DC-102-120S63DC-32-126 ............S63DC-102-126S63DC-32-138 ............S63DC-102-138S63DC-32-162 ............S63DC-102-162S63DC-33-105 ............S63DC-101-107S63DC-33-120 ............S63DC-101-120S63DC-33-132 ............S63DC-96-130S63DC-34-86 ..............S63DC-101-86S63DC-37-82 ..............S63DC-96-82.50S63DC-41-120 ............S63DC-101-120 CM9S63DC-41-130 ............S63DC-96-130 CM9S63DC-41-140 ............S63DC-101-140 CM9S63DC-44-111 ............S63DC-97-111S63DC-44-123 ............S63DC-97-123S63DC-44G-111 .........S63DC-97-111S63DC-44G-123 .........S63DC-97-123S63DC-45-120 ............S63DC-102-120S63DC-45-126 ............S63DC-102-126S63DC-45-138 ............S63DC-102-138S63DC-45-150 ............S63DC-102-150S63DC-45-162 ............S63DC-102-162S63DC-45G-120 .........S63DC-102-120S63DC-45G-126 .........S63DC-102-126S63DC-45G-138 .........S63DC-102-138S63DC-45G-162 .........S63DC-102-162S63DC-46-107 ............ S63DC-101-107 CM37S63DC-46-126 ............S63DC-97-123 CM37S63DC-47-104 ............S63DC-101-104S63DC-47-107 ............S63DC-101-107S63DC-47-120 ............S63DC-101-120S63DC-47-126 ............S63DC-101-126S63DC-47-130 ............S63DC-96-130S63DC-47-140 ............S63DC-101-140S63DC-47-150 ............S63DC-101-150S63DC-47-77 ..............S63DC-101-77

    Commercial / ParkerS63DC-47-82 ..............S63DC-96-82.50S63DC-47-86 ..............S63DC-101-86S63DC-47-92 ..............S63DC-101-92S63DC-47G-104 .........S63DC-101-104S63DC-47G-107 .........S63DC-101-107S63DC-47G-120 .........S63DC-101-120S63DC-47G-126 .........S63DC-101-126S63DC-47G-130 .........S63DC-96-130S63DC-47G-140 .........S63DC-101-140S63DC-47G-77 ...........S63DC-101-77S63DC-47G-82 ...........S63DC-96-82.50S63DC-47G-86 ...........S63DC-101-86S63DC-48-120 ............S63DC-101-120S63DC-48-130 ............S63DC-96-130 CM9S63DC-48-140 ............S63DC-101-140 CM9S63DC-50-105 ............S63DC-101-107S63DC-50-120 ............S63DC-101-120S63DC-50-132 ............S63DC-96-130S63DC-52-77 ..............S63DC-101-77S63DC-53-86 ..............S63DC-101-86S63DC-5-82 ..................S63DC-96-82.50 CM11S63DC-66-111 ............S63DC-96-111S63DC-66-123 ............S63DC-96-130S63DC-66-130 ............S63DC-96-130S63DC-66-82 ..............S63DC-96-82.50S63DC-6-82 ..................S63DC-96-82.50 CM11S63DC-72-130 ............S63DC-96-130S63DC-76-130 ............S63DC-96-130S63DC-81-111 ............S63DC-96-111S63DC-81-82.50 .........S63DC-96-82.50S63DC-83-103.94 .......S63DC-101-104S63DC-83-107 ............S63DC-101-107S63DC-83-120 ............S63DC-101-120S63DC-83-126 ............S63DC-101-126S63DC-83-130 ............S63DC-96-130S63DC-83-140 ............S63DC-101-140S63DC-83-150 ............S63DC-101-150S63DC-83-77 ..............S63DC-101-77S63DC-83-82 ..............S63DC-96-82.50S63DC-83-86 ..............S63DC-101-86S63DC-83-92 ..............S63DC-101-92S63DC-84-106 ............S63DC-60-106S63DC-84-125 ............S63DC-60-125S63DC-84-79.12 .........S63DC-60-79.12S63DC-84-92 ..............S63DC-60-92S63DC-86-111 ............S63DC-97-111S63DC-86-123 ............S63DC-97-123S63DC-87-120 ............S63DC-102-120S63DC-87-126 ............S63DC-102-126S63DC-87-138 ............S63DC-102-138S63DC-87-150 ............S63DC-102-150S63DC-87-162 ............S63DC-102-162S63DC-92-67 ..............S63DC-79-67S63MB-11-108 ...........S63MB-11-108S63MB-1-120 .............S63MB-9-120S63MB-1-140 .............S63MB-8-140S63MB-2-120 .............S63MB-9-120S63MB-5-108 .............S63MB-11-108S63MB-8-120 .............S63MB-9-120S63MB-8G-140 ...........S63MB-8-140S63MB-9G-120 ...........S63MB-9-120S64DB-1-135 ..............S64DB-12-135S64DB-1-156 ..............S64DB-12-156S64DB-2-135 ..............S64DB-12-135S64DB-2-156 ..............S64DB-12-156S64DB-3-135 ..............S64DB-12-135S64DB-3-156 ..............S64DB-12-156S64DB-4-135 ..............S64DB-12-135S64DB-4-156 ..............S64DB-12-156S64DB-5-135 ..............S64DB-12-135S64DB-5-156 ..............S64DB-12-156S64DB-6-135 ..............S64DB-12-135S64DB-6-156 ..............S64DB-12-156S64DB-6G-135 ...........S64DB-12-135S64DB-6G-156 ...........S64DB-12-156S64DB-6G-156R ........S64DB-12-156S64DC-1-157 ..............S64DC-15-157S64DC-13-157 ............S64DC-15-157

    Commercial / Parker S64DC-14-156 ............S64DC-14-156S64DC-2-157 ..............S64DC-15-157S64DC-4-156 ..............S64DC-14-156S64DC-5-156 ..............S64DC-14-156S64DC-7-157 ..............S64DC-15-157S64DC-7G-157 ...........S64DC-15-157S64DC-9-156 ..............S64DC-14-156S64DC-9G-156 ...........S64DC-14-156S64DD-1-157 ..............S64DC-15-157S64MB-1-140 .............S64MB-4-140S64MB-4-140 .............S64MB-4-140S73CC-17-110 ............S73DC-66-110S73CC-18-119 ............S73DC-66-120 CM38S73CC-20-119 ............S73DC-66-120 CM11S73CC-20-124 ............S73DC-66-124 CM11S73CC-22-110 ............S73DC-66-110S73CC-22-124 ............S73DC-66-124S73DC-22-110 ............S73DC-66-110S73DC-22-124 ............S73DC-66-124S73DC-30-110 ............S73DC-66-110S73DC-30-124 ............S73DC-66-124S73DC-30-129 ............S73DC-66-129S73DC-30-140 ............S73DC-66-140S73DC-32-129 ............S73DC-66-129S73DC-32-140 ............S73DC-66-140S73DC-35-120 ............S73DC-66-120S73DC-40-110 ............S73DC-66-110S73DC-40-120 ............S73DC-66-120S73DC-40-124 ............S73DC-66-124S73DC-40-129 ............S73DC-66-129S73DC-40-140 ............S73DC-66-140S73DC-40-150 ............S73DC-66-150S73DC-40G-110 .........S73DC-66-110S73DC-40G-120 .........S73DC-66-120S73DC-40G-124 .........S73DC-66-124S73DC-40G-140 .........S73DC-66-140S73DC-40G-150 .........S73DC-66-150S73DC-41-129 ............S73DC-66-129S73DC-41-140 ............S73DC-66-140S73DC-41G-129 .........S73DC-66-129S73DC-60-125 ............S73DC-60-125S73DC-60-142 ............S73DC-60-142S74CC-22-120 ............S74DC-74-120S74CC-22-134 ............S74DC-74-135S74CC-22-161 ............S74DC-74-161S74DC-22-120 ............S74DC-74-120S74DC-22-134 ............S74DC-74-135S74DC-22-161 ............S74DC-74-161S74DC-30-120 ............S74DC-74-120S74DC-30-135 ............S74DC-74-135S74DC-30-138 ............S74DC-74-135S74DC-30-140 ............S74DC-74-140S74DC-30-156 ............S74DC-74-156S74DC-30-161 ............S74DC-74-161S74DC-3-134 ..............S74DC-74-135S74DC-32-131 ............S74DC-77-135S74DC-40-120 ............S74DC-74-120S74DC-40-135 ............S74DC-74-135S74DC-40-135-OX .....S74DC-75-135S74DC-40-138 ............S74DC-74-135S74DC-40-140 ............S74DC-74-140S74DC-40-156 ............S74DC-74-156S74DC-40-161 ............S74DC-74-161S74DC-40-167 ............S74DC-74-167S74DC-40-180 ............S74DC-74-180S74DC-40A-120 .........S74DC-74-120S74DC-40A-140 .........S74DC-74-140S74DC-40AG-120 ......S74DC-74-120S74DC-40AG-140 ......S74DC-74-140S74DC-40G-135 .........S74DC-74-135S74DC-40G-156 .........S74DC-74-156S74DC-40G-161 .........S74DC-74-161S74DC-40G-180 .........S74DC-74-180S74DC-41-135 ............S74DC-77-135S74DC-42-135 ............S74DC-74-135S74DC-42-156 ............S74DC-74-156S74DC-42-161 ............S74DC-74-161S74DC-51-161 ............S74DC-74-161

    Quick Reference Guide

    Crossover and Application Data is for Reference Purpose Only. No Other Conditions are Expressed or Implied.Note: It is the Users Responsibility to Verify if the Replacement Cylinder is Interchangeable.Note: In some applications, modifi cations may be required for proper cylinder installation.

  • 34 Parker Hannifi n CorporationMobile Cylinder DivisionYoungstown, OH

    Commercial / Parker S74DC-5-135 ..............S74DC-77-135S74DC-60-165.75 .......S74DC-60-165.75S74DC-61-135 ............S74DC-75-135S74DC-6-135 ..............S74DC-74-135S74DC-68-135 ............S74DC-75-135S74DC-71-161 ............S74DC-74-161S74DC-72-135 ............S74DC-77-135S74DC-73-161 ............S74DC-74-161S74MB-2-154 .............S74MB-3-154S74MB-3G-154 ...........S74MB-3-154S74MB-3G-172 ...........S74MB-3-172S83DC-26-134 ............S83DC-56-134S83DC-30-139 ............S83DC-56-139S83DC-32-139 ............S83DC-56-139S83DC-33-139 ............S83DC-56-139 CM19S83DC-40-139 ............S83DC-56-139S83DC-54-134.62 .......S83DC-56-134S83DC-6-134 ..............S83DC-56-134S84CC-22-134 ............S84DC-66-140S84CC-22-149 ............S84DC-66-148S84CC-22-155 ............S84DC-66-161S84CC-22-172 ............S84DC-66-180S84CC-22-183 ............S84DC-66-188S84CC-23-183 ............S84DC-66-180S84CC-4-183 ..............S84DC-66-188S84CC-6-134 ..............S84DC-66-140S84CC-6-149 ..............S84DC-66-148S84CC-6-183 ..............S84DC-66-180S84CC-8-166 ..............S84DC-66-161 CM38S84CC-8-183 ..............S84DC-66-180 CM38S84DB-1-186 ..............S84DC-66-188 CM22S84DC-22-134 ............S84DC-66-140S84DC-22-149 ............S84DC-66-148S84DC-22-155 ............S84DC-66-161S84DC-22-161 ............S84DC-66-161S84DC-22-172 ............S84DC-66-180S84DC-22-183 ............S84DC-66-180S84DC-25-134 ............S84DC-66-140S84DC-25-149 ............S84DC-66-148S84DC-25-161 ............S84DC-66-161S84DC-25-183 ............S84DC-66-180S84DC-30-134 ............S84DC-66-140S84DC-30-149 ............S84DC-66-148S84DC-30-161 ............S84DC-66-161S84DC-30-183 ............S84DC-66-180S84DC-31-156 ............S84DC-66-156S84DC-31G-156 .........S84DC-66-156S84DC-40-134 ............S84DC-66-140S84DC-40-140 ............S84DC-66-140S84DC-40-148 ............S84DC-66-148S84DC-40-149 ............S84DC-66-148S84DC-40-161 ............S84DC-66-161S84DC-40-170 ............S84DC-66-170S84DC-40-180 ............S84DC-66-180S84DC-40-183 ............S84DC-66-180S84DC-40-188 ............S84DC-66-188S84DC-40G-140 .........S84DC-66-140S84DC-40G-148 .........S84DC-66-148S84DC-40G-161 .........S84DC-66-161S84DC-40G-170 .........S84DC-66-170S84DC-40G-180 .........S84DC-66-180S84DC-40G-188 .........S84DC-66-188S84DC-4-134 ..............S84DC-66-140S84DC-4-149 ..............S84DC-66-148S84DC-4-183 ..............S84DC-66-188S84DC-45-134 ............S84