  • PH3199 Physics Lab 3A Experiment 1: Introduction to LabVIEW

    Name of Student: Wong De Wei Shawn

    Name of Partner: Soh Chin Sheng Date of Experiment: 11/09/13

    Date of Report: 20/09/13

    Introduction

    Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) developed by National Instruments, is a graphical programming platform that helps engineers and scientists design and test small to large systems. It offers unprecedented integration with existing legacy software, IP, and hardware while incorporating the latest computing technologies. (National Instruments, 2013)

    Figure 1: DAQ Signal Accessory

    Figure 1 show Data Acquisition (DAQ) Signal Accessory with the IC temperature sensor which is wired to the Analog Input channel that produces a voltage output linearly proportional to the temperature; = 100.

    Objectives

    Design a program that will allow the user to input the maximum and the minimum temperature limits and check if this limit is valid, if not alert the user with a LED indicator and alarm.

    Obtain the current temperature from the furnace in a Sub VI and output the current, maximum and minimum temperature on a waveform chart.

    If the current temperature is outside the maximum and minimum temperature range, display a warning message with a LED indicator and alarm to alert the user.

    Output the current temperature into a text-based measurement file. The user is able to start or end the temperature data acquisition.

    IC Temperature Sensor

    1

  • Experimental Procedure

    This is a diagrammatic representation of the program algorithm.

    The user is required to configure the write to measurement file settings.

    If the User input of maximum and minimum temperature is not logical, a warning message will be displayed with a LED indicator and alarm; which will be listed in the Front panel under System status with the date and time.

    The user can start or end the data acquisition by clicking on the Enable Acquiring Data button. The user can end the program by clicking on the End Task button.

    If the current temperature is less than minimum temperature or more than maximum temperature, a warning message will be displayed with a LED indicator and alarm; which will be listed in the Front panel under System status with the date and time.

    In summary, the program validates the user input data and alerts the user if the current temperature is outside the limits. The Front panel allows the user to control the start or end of the data acquisition.

    Start

    User input maximum and minimum temperature

    Warning Maximum and Minimum Temperature limits are invalid. Please re-input values.

    Is Minimum < Maximum?

    Enable Acquiring Data

    Minimum < Current < Maximum Current > Maximum Current < Minimum

    Warning Current Temperature > Maximum Temperature

    Warning Current Temperature < Minimum Temperature

    End Task

    Configure write to measurement file

    Yes

    No

    2

  • Front Panel

    Figure 2: Front Panel

    Components

    1. Enable Acquiring Data button - Control for the user to start or end the data acquisition.

    2. Current temperature display - Displays the numerical value of the current temperature obtained from the furnace.

    3. User input for Maximum temperature - Numerical input with increment and decrement buttons in steps of 1.

    4. User input for Minimum temperature - Numerical input with increment and decrement buttons in steps of 1.

    5. Waveform Chart of Temperature vs Time - Red is the Maximum temperature - White is the Current temperature - Green is the Minimum temperature

    6. System status - Warning messages and system status is displayed with date and time.

    7. Minimum > Maximum temperature LED indicator - Turns on when the user inputs a minimum value greater than the maximum value.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    3

  • 8. Current < Minimum temperature LED indicator

    - Turns on when the current temperature falls below the minimum temperature.

    9. Current > Maximum temperature LED indicator - Turns on when the current temperature rise above the maximum temperature.

    10. End Task button - Control for the user to end the program.

    4

  • Block Diagram

    Sub VI

    Figure 3: DAQ Assistant inside the Sub VI

    The function is to obtain data directly from the temperature sensor. The data collection is set to on demand. The voltage output from the DAQ Assistant is multiplied by a numerical constant of 100 to obtain the temperature reading in Degree Celsius (Figure 3).

    Main VI

    The Main VI is broken down into Region I, II and III for easier referencing.

    Region I

    Figure 4: Region I - True

    The minimum and maximum temperatures are inputs from the user via the front panel. The input values are then validated. If the input minimum temperature value is greater than the maximum temperature value, the program will show this warning message Warning Maximum and Minimum Temperature limits are invalid. Please re-input values. The LED indicator will turn on, an alarm will sound off and the warning message will be shown on the system status with the date and time. The program will prompt the user to re-input the values. The LED indicator and alarm will remain on until the minimum value is smaller than the maximum value (Figure 4).

    5

  • Figure 5: Region I - False

    If the input minimum temperature value is smaller than the maximum temperature value, the program will show this Maximum and Minimum Temperature limits are valid. on the system status (Figure 5).

    Region II

    Figure 6: Region II - True

    The Current temperature is obtained from the Sub VI and compared with the Maximum and Minimum temperatures.

    If the Current temperature is lower than the Minimum temperature, the program will show this warning message Warning Current Temperature < Minimum Temperature. The LED indicator

    6

  • will turn on, an alarm will sound off and the warning message will be shown on the system status with the date and time.

    If the Current temperature is greater than the Maximum temperature, the program will show this warning message Warning Current Temperature > Maximum Temperature. The LED indicator will turn on, an alarm will sound off and the warning message will be shown on the system status with the date and time (Figure 6).

    Figure 7: Region II - False

    If the Current temperature is within the Maximum and Minimum temperature range, the program will not show any warning messages on the system status (Figure 7).

    Figure 8: Waveform chart

    The Current temperature, Maximum temperature and Minimum temperature are output into a waveform chart of Temperature vs Time in the Front Panel. Current Temperature, Maximum Temperature and Minimum Temperature are reflected as a white line, red line and green line respectively (Figure 8).

    7

  • Region III

    Figure 9: Block diagrams Figure 10: Configuration for Write to Measurement file

    The Current temperature data is written to a Measurement file which allows the user to control through the Enable Acquiring Data button (Figure 9). The user is given the options to configure the File name, File format, location to save at and action to take if a file already exists (Figure 10).

    8

  • Region I, II, III

    Figure 11: Block Diagram for All True

    Figure 12: Block Diagram for All False

    The entire Block diagram is placed in a while loop which terminates with the End Task button. Figure 11 shows the Block diagram for All True conditions and Figure 12 shows the Block diagram for All False conditions.

    9

  • Operation

    Invalid user input

    Figure 13: Invalid user input of Maximum and Minimum values

    If the User input of maximum and minimum temperature is not logical where minimum value is greater than maximum value, a warning message will be displayed with a LED indicator and alarm; which will be listed in the Front panel under System status with the date and time (Figure 13).

    Current temperature below Minimum temperature

    Figure 14: Current temperature < Minimum temperature

    10

  • The System status will show this warning message Warning Current Temperature < Minimum Temperature with the date and time. The Current Temperature < Minimum Temperature LED indicator will turn on and an alarm will sound off (Figure 14).

    Current temperature above Maximum temperature

    Figure 15: Current temperature > Maximum temperature

    The System status will show this warning message Warning Current Temperature > Maximum Temperature with the date and time. The Current Temperature > Maximum Temperature LED indicator will turn on and an alarm will sound off (Figure 15).

    11

  • MathScript

    The raw data obtained from measurement in an unenclosed system does not always immediately convey useful information. The transformation of the signal, removing noise disturbances, correcting for data corrupted by faulty equipment, or compensating for environmental effects, such as temperature and humidity are essential. Hence, Signal Processing, the analysis, manipulation and interpretation of signals with the purpose of noise reduction, classication, amplification and filtering (Jahromi, 2007), is a fundamental necessity in virtually all engineering or scientific applications.

    The LabVIEW MathScript RT Module allows .m files in line with the acquisition of data, thus