Direktorat Jenderal Pendidikan Tinggi

Kementerian Pendidikan Tinggi dan Kebudayaan

SeminarSeminar

PROTEKSI JIWA TERHADAP KEBAKARAN

PADA RUMAH SAKIT BERTINGKATJakarta, 20.03.2014

Dr. Ir. Aswito Asmaningprodjo, MSA

Page 2: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

BENCANA KEBAKARAN RUMAH SAKIT DI INDONESIAJARANG TERJADI

TETAPI JANGAN DIARTIKAN BANGUNAN RUMAH SAKIT DITETAPI JANGAN DIARTIKAN BANGUNAN RUMAH SAKIT DI INDONESIA AMAN KEBAKARAN

HASIL RISET THESIS ARSITEKTUR ITB 1996 MENYATAKAN :

DARI 4 RUMAH SAKIT BERTINGKAT TERKENAL DI BANDUNG3 TERNYATA TIDAK AMAN KEBAKARAN3 TERNYATA TIDAK AMAN KEBAKARAN1 AMAN DENGAN SEJUMLAH CATATAN

Page 3: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

MENGAPA BANYAK RUMAH SAKIT TIDAK AMAN KEBAKARAN

KARENA UMUMNYA PARA PERENCANA BARU MENERAPKAN STANDAR KEAMANAN BANGUNAN UMUM TERHADAP KEBAKARANSTANDAR KEAMANAN BANGUNAN UMUM TERHADAP KEBAKARANBELUM KEBUTUHAN KHUSUS RUMAH SAKIT YAITU KESELAMATANJIWA PENGHUNI YANG MEMPUNYAI KARAKTERISTIK KONDISI FISIK DAN MENTAL TERTENTUFISIK DAN MENTAL TERTENTU

MENGAPA BANYAK DESAIN ARSITEKTUR RUMAH SAKIT TIDAK AMAN KEBAKARANAMAN KEBAKARAN

KARENA MASIH LANGKA PERENCANA YANG MENGGELUTI ASPEK KESELAMATAN JIWA TERHADAP KEBAKARAN TERLEBIH TENTANGKESELAMATAN JIWA TERHADAP KEBAKARAN TERLEBIH TENTANG BANGUNAN RUMAH SAKIT

STANDAR TEKNIK DESAIN RUMAH SAKIT YANG ADA BELUM CUKUPSTANDAR TEKNIK DESAIN RUMAH SAKIT YANG ADA BELUM CUKUP LENGKAP. MASIH BANYAK YANG DAPAT DIACU DARI LIFE SAFETYCODE DARI NFPA DLL

Page 4: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

PERMASALAHAN KEBAKARAN RUMAH SAKIT BERTINGKAT :

• BUTUH WAKTU LEBIH LAMA UNTUK EVAKUASI PENGHUNI• RISIKO TERHADAP ASAP DAN GAS PANAS• BAHAN PELAPIS INTERIOR DAN BAHAN MUDAH TERBAKAR• BUTUH KEAMANAN STRUKTUR TERHADAP BAHAYA KEBAKARAN• DETEKTOR DAN SISTEM ALARM YANG ANDAL• SISTEM PEMADAMAN API• SALURAN AC DAN SERVISIS GEDUNG• PEMADAMAN API DARI LUAR MENJADI KURANG EFEKTIF• PROBLEMA ALUMUNIUM DAN SISTEM DINDING KACA• PROBLEMA GEDUNG ATRIUM• PERILAKU MANUSIA DALAM KEBAKARAN

Page 5: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

RUMAH SAKIT BERTINGKAT

DI KOTA BESAR, INDONESIATUMBUH KARENA LANGKA DAN

MAHALNYA LAHAN KOTA

Page 6: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

PERMASALAHAN BANGUNAN RUMAH SAKIT BERTINGKAT :• LUAS LANTAI YANG BESAR• PEMAKAIAN ENERGI LISTRIK BESAR• PENGGUNAAN BAHAN MUDAH TERBAKAR SEMAKIN BESAR• JUMLAH PENGHUNI YANG BANYAK • BERMACAM KARAKTERISTIK KONDISI FISIK DAN MENTAL PENGHUNI

DAMPAK KEBAKARAN TERHADAP PERILAKU PENGHUNI• DAMPAK KEBAKARAN TERHADAP PERILAKU PENGHUNI• PERLU JALUR EVAKUASI YANG CUKUP DAN AMAN• REGU EVAKUASI YANG CUKUP, TERAMPIL DAN SIAGA.• BANGUNAN DIMANA PENGHUNI BERADA DALAM KONDISI TIDUR

EVAKUASI AKAN SEMAKIN KOMPLEKEVAKUASI AKAN SEMAKIN KOMPLEK• EVAKUASI HORISONTAL LEBIH MUDAH, RINGAN DAN AMAN MENUJU

KOMPARTEMEN TERPROTEKSIKOMPARTEMEN TERPROTEKSI• EVAKUASI VERTIKAL LEBIH BERISIKO, LAMA. TERUTAMA BAGI LANSIA

DAN DEFABEL

Page 7: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

KELEMAHAN PADA SEJUMLAH DESAIN RS BERTINGKATKELEMAHAN PADA SEJUMLAH DESAIN RS BERTINGKAT :• BANYAK RS MENGGUNAKAN ATRIUM PADA ZONA LOBI UTAMA ATAU ZONA KAMAR

INAP UNTUK MENDAPAT KESAN INTERIOR MEGAH. DALAM HAL INI ATRIUM AKAN MENJADI SEBAGAI RONGGA PENYEBAR ASAP

• BANYAK TANGGA SERVIS DIFUNGSIKAN JUGA SEBAGAI TANGGA KEBAKARAN YANG TIDAK DIPROTEKSI SEHINGGA MERUPAKAN CEROBONG ASAP YANG BERBAHAYA BAGI EVAKUASI

• BANYAK KORIDOR PANJANG LEBIH DARI 45 M TANPA SPRINKLER DAN KORIDORBUNTU LEBIH DARI 15 M

• BANYAK KORIDOR PANJANG TIDAK DILENGKAPI PINTU PENYEKAT ASAP GUNA MENCEGAH PENYEBARAN ASAP DENGAN KETAHANAN API 1 JAM

• ADA TANGGA KEBAKARAN YANG TERSEMBUNYI LOKASINYA, SUSAH DIAKSES,• BANYAK TANGGA DIJADIKAN GUDANG PENYIMPAN BARANG• ADA RUANG INAP PASIEN TIDAK BERPINTU. ADA YANG BERPINTU TETAPI DAUN

PINTUNYA TIDAK MEMILIKI KETAHANAN API 20 MENIT• BANYAK KORIDOR DAN RUANG UJUNG KORIDOR DI JADIKAN RUANG

SIMPAN BARANG• ADA RUANG INAP YANG TIDAK DIPASANG SMOKE DETEKTOR YG DIHUBUNGKANADA RUANG INAP YANG TIDAK DIPASANG SMOKE DETEKTOR YG DIHUBUNGKAN

DENGAN ALARM

Page 8: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

PROSES KEBAKARAN

BAHAYA KEBAKARAN

Page 9: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

PROSES PERTUMBUHAN API

Page 10: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo
Page 11: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

PERILAKU MANUSIA DLM KEBAKARAN

Page 12: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

5 KARAKTERISTIK PENGHUNI RS PERILAKU YANG TIDAK MENUNJANG

• RISIKO TIDUR

EFEKTIFITAS EVAKUASI

(SLEEPING RISK)

• JUMLAH PASIEN

(NUMBER OF PATIENS)

• PERILAKU PANIK

(PANIC BEHAVIOR)

• PERILAKU MASUK KEMBALI(NUMBER OF PATIENS)

• MOBILITAS

(MOBILITY)

• PERILAKU MASUK KEMBALI

(RE-ENTRY BEHAVIOR)

• PERILAKU DLM MEMADAMKAN( )

• PENGENALAN

(FAMILIARITY)

KEBAKARAN

• RESPON THD ALARM

(RESPONS TO FIRE ALARM)

Page 13: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

SARANA EVAKUASI BAGI PASIEN TERKENDALAPASIEN TULI PERLU ALAT KOMUNIKASI YANG TANPA SUARA• PASIEN TULI : PERLU ALAT KOMUNIKASI YANG TANPA SUARA

• PASIEN KURSI RODA : PERLU ALAT ALARM YANG DITEMPATKAN PADA

JANGKAUAN TANGANNYA, YAITU MAKSIMUM 1,2 M

PROBLEM EVAKUASI• PASIEN TERKENDALA PENDENGARAN :

TIDAK MENDE3NGAR ALARM SISTEM KOMUNIKASI UMUM ATAU YANG LAINTIDAK MENDE3NGAR ALARM, SISTEM KOMUNIKASI UMUM ATAU YANG LAIN

• PASIEN TERKENDALA MENTAL :

TIDAK DAPAT MENGERTI INSTRUKSI, TIDAK BISA MEMAHAMI SITUASI,

TIDAK MENGERTI PENTINGNYA JALUR EVAKUASI

• PASIEN TERKENDALA PENGELIATAN :

TIDAK BISA MELIHAT LOKASI KEBAKARAN TIDAK BISA DIARAHKANTIDAK BISA MELIHAT LOKASI KEBAKARAN, TIDAK BISA DIARAHKAN

DENGAN RAMBU EKSIT PADA GEDUNG YANG TIDAK DIKENALINYA

• PASIEN TERKENDALA MOBILITAS :PASIEN TERKENDALA MOBILITAS :

PADA LANTAI DGN PERMUKAAN MIRING/ RAMP, PERLU AMAN GUNA

MENEKAN WAKTU UNTUK EVAKUASI

Page 14: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

PENGARUH BENTUK KANOPI TERHADAP PENYEBARAN API

Page 15: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

ATRIUM & PENJALARAN ASAP

Page 16: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

KOMPARTEMEN / EVAKUASI HORISONTAL

JALUR EVAKUAS VERTIKALJALUR EVAKUAS VERTIKAL

Page 17: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo
Page 18: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

KOMPARTEMENISASI

• SISTEM KOMPARTEMEN PENTING UNTUK DESAIN RUMAH SAKIT• DINDING PENYEKAT KOMPARTEMEN DIBANGUN DARI LANTAI KE LANTAI

SEHINGGA TIDAK ADA RUANG MENERUS DI ATAS PLAFON DAN TIDAK ADAASAP, GAS,API BERPENETRASI MASUK DARI RUANG DI LUARNYA

• DINDING BERDAYA TAHAN API MIN 1 JAM DGN KETAHANAN PINTU 20 MENIT• KOMPARTEMEN BERFUNGSI SEBAGAI RUANG PENYELAMATAN SEMENTARA• KOMPARTEMEN DIUTAMAKAN PADA RUANG INAP/ RAWAT PASIEN, RUANG

BEDAH, ICU, ICCU, REFUGEE FLOOR DLL• UTAMAKAN EVAKUASI HORISONTAL DARI KOMPARTEMEN KE KOMPARTEMENUTAMAKAN EVAKUASI HORISONTAL DARI KOMPARTEMEN KE KOMPARTEMEN

LAIN YANG AMAN• KAPASITAS RUANG INAP MAKS 50 PASIEN DGN PANJANG KORIDOR TIDAK

LEBIH DARI 45 M BERSPRINKLERLEBIH DARI 45 M BERSPRINKLER

Page 19: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo
Page 20: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

FORMAT NFPA : KEHANDALAN

BANGUNAN THP KEBAKARANBANGUNAN THP KEBAKARAN

Page 21: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

FORMAT NFPA : KEHANDALAN

BANGUNAN THP KEBAKARAN

Page 22: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

CONTOH DENAH ZONA

RAWAT INAP

Page 23: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

CONTOH DENAH ZONA

RAWAT INAP

Page 24: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

CONTOH DENAH ZONA

RAWAT INAP

Page 25: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

CONTOH DENAH ZONA

RAWAT INAP

Page 26: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

CONTOH DENAH ZONACONTOH DENAH ZONA

RAWAT INAP

Page 27: 2 slide proteksi_jiwa_terhadap_kebakaran_aswito_asmaningprojo

CONTOH TAMPAK DEPANCONTOH TAMPAK DEPAN GEDUNG A RSCM